![Coastcom D/I Mux III System User Manual Download Page 3](http://html.mh-extra.com/html/coastcom/d-i-mux-iii-system/d-i-mux-iii-system_user-manual_2628616003.webp)
D/I MUX III User’s Manual
i
RELEASE NOTE
December 2005
UPGRADED –24VDC Power Supply for D/I Mux III
Coastcom has released part number 30314-902, -24Volt DC Power Supply to replace 30314-101.
30314-902 Power Supply –24 VDC Redundant
The 30314-902 is a DC-to-DC converter used to power D/I Mux equipment from an external -24 VDC
input supply. Gen/-12 and +/-5 volt outputs as well as failure alarm signals. Also provides
primary (-24v) power fusing. Can be used in a redundant or load sharing configuration when two power
supplies are installed. When configured with FXS cards order modular Ring Generator 30333-121. Can
be used in an 8/12/24 slot chassis. Replaces 30314-101.
RELEASE NOTE
August 2005
UPGRADED POWER SUPPLY UNITS FOR D/I Mux III
In August 2005, Coastcom released upgraded power supply units for the D/I Mux III. The
following two new units replace part numbers 30338-102, 30315-105A, 30338-103A, and 30308-
102A.
30338-902 Power Supply -48 VDC Redundant
The 30338-902 is a DC-to-DC converter used to power D/I Mux equipment from an external -48 VDC
input supply. Gen/-12 and +/-5 volt outputs as well as failure alarm signals. Also provides
primary (-48v) power fusing. Can be used in a redundant or load sharing configuration when two power
supplies are installed. When configured with FXS cards order modular Ring Generator 30333-101. Can
be used in an 8/12/24 slot chassis. Replaces 30338-102.
30315-505 Power Supply 120 VAC
An AC/DC self-contained single-slot power supply that provides all of the voltages necessary to
operate a D/I Mux III - except ringing voltage. When configured with FXS feature cards, order
modular Ringing Generator 30333-101. Pr/-12, +/-5, and –48 volts. Can be used in an
8/12/24 slot chassis. Replaces a 30308-102A and the combination option of 30315-105A with
30338-103A.
Cannot be used in combination with any other power supply.
Summary of Contents for D/I Mux III System
Page 20: ......
Page 36: ...Chapter 1 System Overview and Modes of Operation 16 ...
Page 51: ...Chapter 1 System Overview and Modes of Operation 31 ...
Page 79: ...Chapter 3 Installation 59 ...
Page 232: ...D I Mux III User s Manual Appendix B 24 Volt Systems 212 APPENDIX B 24 VOLT SYSTEMS ...
Page 237: ...D I Mux III User s Manual Appendix D Preconfigured Maps APPENDIX D PRECONFIGURED MAPS ...
Page 243: ...D I Mux III User s Manual Appendix E SNMP APPENDIX E SNMP ...
Page 265: ...D I Mux III User s Manual Appendix G Modem Interfaces APPENDIX G MODEM INTERFACES ...
Page 284: ...D I Mux III User s Manual Appendix H Set Report Options APPENDIX H SET REPORT OPTIONS ...