◄ Error caused when SENSOR 1 and SENSOR 3 have been plugged in incorrectly. Swap the
SENSOR 1 and SENSOR 3 plug in controller to correct this problem.
Check SENSOR 1 connection. ►
◄ Error caused by no water flow through heater or no water in heater. Check to be sure there is
enough water flow through heater.
Check SENSOR 1 connection or replace SENSOR 1. ►
◄ Wait for water temperature to cool down.
Check SENSOR 2 connection. ►
◄ Wait for water temperature to cool down. Check to be sure there is enough water flow through
heater.
Check SENSOR 2 connection or replace SENSOR 2. ►
◄ Wait for water temperature to cool down. Check to be sure there is enough water flow through
heater.
Check SENSOR 3 connection. ►
◄ Error caused when SENSOR 1, 2, or 3 detects low temperature. All
PUMPS
and BLOWERS
will turn on automatically to protect plumbing from freezing.
PUMPS
and BLOWERS will shut
down when all 3 SENSORS reach a desired temperature.
Check SENSOR 3 connection or replace SENSOR 3. ►