Operating Instructions
RaptorX-SL-Series
CNC-STEP e.K. ▪ Siemensstrasse 13-15 ▪ 47608 Geldern ▪ Germany
Page 98
Support: +49 (0)2831/91021-50
06.10.2010
Fig. 48: Secure main switch
2.
Secure against restarting by using a padlock (Fig. 48).
DANGER!
Risk of death by electrocution from stored
energy!
Electrical charge may be stored in electrical
components which could result in electrocution
causing injury or death.
- Before commencing work, turn of the power and
wait for 10 min before continuing, to allow
condensers time to discharge the stored current.
Fig. 49: Controller
3.
Open the controller using the square key supplied
(Fig. 49/1).
4.
Open the door of the controller unit.
5.
Change fuse.
6.
Close and lock door with square key.
7.
Switch on main power supply.
9 . 4
S t a r t - u p a f t e r F a u l t R e p a i r
After repairing a fault, carry out the following steps to restart:
1.
Reset the emergency stop switches.
2.
Acknowledge the faults in the controlling software.
3.
Ensure that there are no persons in the danger area.
4.
Restart operating according to chapter 7 “Operation”, page