![CNC-Step RaptorX-SL1200-S15 Operating Instructions Manual Download Page 61](http://html1.mh-extra.com/html/cnc-step/raptorx-sl1200-s15/raptorx-sl1200-s15_operating-instructions-manual_2627817061.webp)
Operating Instructions
RaptorX-SL-Series
CNC-STEP e.K. ▪ Siemensstrasse 13-15 ▪ 47608 Geldern ▪ Germany
Page 61
Support: +49 (0)2831/91021-50
06.10.2010
Setting-up machine
1.
The machine must be installed with the prescribed method
of attachment on a level, vibration-resistant and fully hard-
ened foundation or floor.
In doubt have all of the required loads checked
by a qualified building engineer.
2.
Remove all transportation equipment and packaging on the
machine at the place of installation.
Levelling of the machine
Fig. 24: machine spirit level
A precision spirit-level capable of 0.02mm accuracy (Fig. 24) is
included in the scope of delivery. Use the supplied spirit level to
level out the CNC machine correctly. Adjustments can be made
on the feet found on each corner of the machine.
Fig. 25: adjustable foot
1.
Loosen the lock nut (Fig. 25/2) with a 17mm spanner.
2.
Adjust height by using 17mm spanner on adjusting nut
(Fig. 25/1).
turn clockwise to lower table,
turn anti-clockwise to raise the table.
3.
Use the spirit level to check the accuracy and if required re-
peat step 2.
4.
When done, secure the lock nut (Fig. 25/2) with a 17mm
spanner.
5.
Check that all axis are free to move.