Installation
3.
Provide a 3 foot/1 meter service loop in the machine power supply cable.
4.
Route the power cable from machine rear to terminal block making sure the cable
does not touch the booster tank.
5.
Connect the power cable to the terminal block bracket using a suitable strain relief
connector.
6.
Connect the power wires according to the wiring diagram on page 6.
Refer to Fig. 7 below:
Connect Power to the Main Terminal Block
ELECTRICAL CONNECTION
GROUND LUG
STRAIN-RELIEF
KNOCKOUT
B
A
L1
L2
L1
L2
208/240V
G
208-240V/60Hz/1
T
WO
POWER WIRES
PLUS
AN ADDITIIONAL WIRE
MUST
BE PROVIDED FOR
MACHINE GROUND.
CONNECT THE INCOMING
POWER AS SHOWN AT LEFT
THREAD THE POWER CABLE
THROUGH THE MIDDLE
SLOT IN THE DISHWASHER
REAR PANEL.
SECURE THE CABLE TO THE
TERMINAL BOX USING THE
PROPER STRAIN RELIEF.
A 30" / 76 cm SERVICE
LOOP MUST BE PROVIDED
BEHIND THE UNIT FOR
SERVICING.
STOP
STOP
A
B