6
Installation
ELECTRICAL CONNECTION
The installation of the dishwasher must comply with all local electrical, plumbing, health and
safety codes or in the absence of local codes, installed in accordance with the applicable
requirements in the National Electrical Code, NFPA 70, Canadian Electrical Code (CEC),
Part 1, CSA C22.1; and the Standard for Ventilation Control and Fire Protection of
Commercial Cooking Operations, NFPA 96.
NOTE:
L1
L2
208-240V
VAC
GRD
SINGLE PHASE POWER CONNECTION
HOW TO CONNECT 1 PHASE POWER
! VE RY IMPO RTANT !
1. Check the data plate on the front of the
dishwasher for the phase of the machine.
2. Remove the lower access panel.
3. Pull power connection box forward out.
4. The Main Terminal Block has connections
for L1, L2 and Ground.
5. Connect ground, then connect
L1, L2 to 208-230 VAC.
7. Main Power connections are complete.
If the data plate says the machine is 1 Phase,
then connect a 1 PH power supply.
DO NOT CONNECT POWER TO L3.
THE ELECTRICAL POWER MUST BE A
2-WIRE PLUS GROUND SUPPLY.
Connect Power to the Main Terminal Block