1.
Install the drain hose to an 1-1/2" or larger "WYE" fitting.
2.
Building drain system must be properly vented.
3.
Connection to a "TEE" fitting will prevent the dishwasher from draining completely
DO
connect the flexible drain hose
to a vented "WYE" connection.
DO NOT
connect the flexible drain
hose to a TEE fitting.
Fig. 3
Installation
Indirect Drain Connection
1.
A 1" (25.4mm) minimum air gap must be maintained between the outlet of the drain
hose and the flood-level rim of the floor drain, floor sink, or any other locally approved
drain receptacle (see Fig. 4).
Minimum
Air Gap
1” [25.4mm]
Floor
Dishwasher
Drain Hose
Floor Drain
! VERY IMPORTANT !
Drain problems are often due to improper installation of the drain hose and may not be
covered by the limited warranty.
Fig. 4