Nozzle
The design of the extending and retracting
douche nozzle prevents it being soiled in
both the rest and active positions. After every
douche operation, the nozzle will be sprayed
and cleaned by a targeted jet of water while
retracting. The following procedure should be
adopted if access is nevertheless required
to the nozzle:
– Remove filter cover
[2]
at bottom left of
the unit:
A small special tool
[17]
can be seen in a
holding clamp behind the filter cartridge
[10]
.
– Remove tool from the holding clamp and
insert with pointed side
[18]
in nozzle from
below as shown in the diagram.
– Withdraw nozzle
[19]
with special tool
[17]
against the spring pressure as far as the
stop and hold with the free hand.
– Turn tool round and insert the forked side
in the annular groove
[20]
of the nozzle
from above as shown in the diagram. This
locks the nozzle.
– Clean nozzle.
– Hold nozzle in one hand, remove the
special tool and slowly return the nozzle
to its initial position.
– Place the special tool back in its holder.
43
- E -
19
18
17
17
20
2
17
18
10