![Cloos GLW 322 Operating Instructions And Spare Parts Download Page 32](http://html1.mh-extra.com/html/cloos/glw-322/glw-322_operating-instructions-and-spare-parts_2625801032.webp)
GLW 322
Cod.006.0001.1861
01/09/2014 v2.0
ENGLISH
31/38
5
TECHNICAL DATA
Directives applied
Waste electrical and electronic equipment (WEEE)
Electromagnetic compatibility (EMC)
Low voltage (LVD)
Restriction of the use of certain hazardous substances (RoHS)
Construction standards
EN 60974-1; EN 60974-3; EN 60974-10 Class A
Conformity markings
Equipment compliant with European directives in force
Equipment suitable in an environment with increased hazard of electric shock
Equipment compliant with WEEE directive
Equipment compliant with RoHS directive
Supply voltage
3 x 400 Va.c. ± 15 % / 50-60 Hz
Mains protection
25 A 500 V Delayed
Z
max
If this equipment is connected to a public low voltage system, it is the responsibility of the
installer or user of the equipment to ensure, by consultation with the distribution network
operator if necessary, that the equipment may be connected.
Dimensions ( L x D x H )
690 x 290 x 450 mm
Weight
42.6 kg
Insulation class
H
Protection rating
IP23S
Cooling
AF: Air-over cooling (fan assisted)
Maximum gas pressure
0,5 MPa (5 bar)
Static characteristic
MMA
Drooping characteristic
TIG
Drooping characteristic
Current and voltage adjustment range
MMA
10 A / 20.4 V - 300 A / 32.0 V
TIG
5 A / 10.2 V - 320 A / 22.8 V
Welding current / Working voltage
MMA
50 % (40° C)
300 A - 32.0 V
60 % (40° C)
280 A - 31.2 V
100 % (40° C)
240 A - 29.6 V
TIG
45 % (40° C)
320 A - 22.8 V
60 % (40° C)
280 A - 21.2 V
100 % (40° C)
240 A - 19.6 V
Maximum input power
MMA
50 % (40° C)
15.5 kVA – 12.1 kW
60 % (40° C)
13.2 kVA – 10.7 kW
100 % (40° C)
11.2 kVA – 8.6 kW
TIG
45 % (40° C)
13.1 kVA – 9.9 kW
60 % (40° C)
10.5 kVA – 7.9 kW
100 % (40° C)
8.6 kVA – 6.3 kW
Maximum supply current
MMA
50 % (40° C)
22.4 A
60 % (40° C)
19.5 A
100 % (40° C)
16.2 A
TIG
45 % (40° C)
18.8 A
60 % (40° C)
14.8 A
100 % (40° C)
12.5 A
Maximum Effective Supply Current
MMA
50 % (40° C)
15.8 A
60 % (40° C)
15.1A
100 % (40° C)
16.2 A
TIG
45 % (40° C)
12.6 A
60 % (40° C)
11.4 A
100 % (40° C)
12.5 A
No-load voltage (U
0
)
MMA
71 V
TIG
66 V
Reduced no-load voltage (U
r
)
MMA
8 V
TIG
8 V
Rated HF peak voltage (U
p
)
11.3 kV
Arc striking device designed to work with manual guided torch.
Summary of Contents for GLW 322
Page 1: ...operating instructions and spare parts GLW 322 Rev 0 EN...
Page 8: ...GLW 322 Cod 006 0001 1861 01 09 2014 v2 0 ENGLISH 7 38 polarity to basic electrode...
Page 10: ...GLW 322 Cod 006 0001 1861 01 09 2014 v2 0 ENGLISH 9 38 polarity for tungsten electrode...
Page 38: ...Remote Controller Potentiometer 2k 10k Foot pedal controller Potentiometer 2k 10k...
Page 39: ...www qineo de...