Tab. 6 - 1st level menu parameters in SYNERGIC TIG mode
ACRONYM
PARAMETER
MIN
DEFAULT
MAX
Pr.G.
PRE-GAS TIME
0.0 s
0.1 s
10.0 s
St.C.
STARTING CURRENT
2 %
5 A
50 %
40 A
200 %
320 A
*2
Sl.u.
UP SLOPE TIME
0.0 s
0.0 s
25.0 s
WELDING CURRENT
MAXIMUM PEDAL CURRENT
5 A
80 A
320 A
*2
S.Cu.
SECOND WELDING CURRENT
10 %
50 %
200 % *1
b.Cu.
BASE CURRENT
*Syn
*Syn
*Syn
PE.t.
PEAK TIME
*Syn
*Syn
*Syn
P.Fr.
PULSED CURRENT FREQUENCY
*Syn
*Syn
*Syn
Sl.d.
DOWN SLOPE TIME
0.0 s
0.0 s
25.0 s
F.Cu.
FINAL CURRENT
5 %
5 A
5 %
5 A
80 %
320 A
Po.G.
POST-GAS TIME
0.0 s
10.0 s
25.0 s
Tab. 7 - 1st level menu parameters in AC TIG mode
ACRONYM
PARAMETER
MIN
DEFAULT
MAX
Pr.G.
PRE-GAS TIME
0.0 s
0.1 s
10.0 s
St.C.
STARTING CURRENT
2 %
5 A
50 %
40 A
200 %
320 A
Sl.u.
UP SLOPE TIME
0.0 s
0.0 s
25.0 s
WELDING CURRENT
MAXIMUM PEDAL CURRENT
5 A
80 A
320 A
*2
S.Cu.
SECOND WELDING CURRENT 10 %
50 %
200 % *1
Sl.d.
DOWN SLOPE TIME
0.0 s
0.0 s
25.0 s
F.Cu.
FINAL CURRENT
5 %
5 A
5 %
5 A
80 %
320 A
Po.G.
POST-GAS TIME
0.0 s
10.0 s
25.0 s
Tab. 8 - 1st level menu parameters in PULSED AC TIG mode
ACRONYM
PARAMETER
MIN
DEFAULT
MAX
Pr.G.
PRE-GAS TIME
0.0 s
0.1 s
10.0 s
St.C.
STARTING CURRENT
2 %
5 A
50 %
40 A
200 %
320 A
Sl.u.
UP SLOPE TIME
0.0 s
0.0 s
25.0 s
WELDING CURRENT
MAXIMUM PEDAL CURRENT
5 A
80 A
320 A
*2
S.Cu.
SECOND WELDING CURRENT
10 %
50 %
200 %
*1
b.Cu.
BASE CURRENT
1 %
40 %
200 %
PE.t.
PEAK TIME
1 %
0.1 s
50 %
5.0 s
99 %
5.0 s
P.Fr.
PULSED CURRENT FREQUENCY 0.1 Hz
100 Hz
2.5 kHz
bA.t.
BASE TIME
0.1 s
5.0 s
5.0 s
Sl.d.
DOWN SLOPE TIME
0.0 s
0.0 s
25.0 s
F.Cu.
FINAL CURRENT
5 %
5 A
5 %
5 A
80 %
320 A
Po.G.
POST-GAS TIME
0.0 s
10.0 s
25.0 s
*1:
This parameter is set as a percentage referred to the value of the following parameter:
WELDING CURRENT
*2:
This setting is used to adjust both parameters.
*SYN: This code indicates that parameters control is synergic.
The optimal value of this parameter is set automatically by the microprocessor on the basis of the preset welding current value.
When SYN is installed, to display the synergic value press the following button: S3
This value can be displayed but it is not user-adjustable.
Summary of Contents for GLW 322
Page 1: ...operating instructions and spare parts GLW 322 Rev 0 EN...
Page 8: ...GLW 322 Cod 006 0001 1861 01 09 2014 v2 0 ENGLISH 7 38 polarity to basic electrode...
Page 10: ...GLW 322 Cod 006 0001 1861 01 09 2014 v2 0 ENGLISH 9 38 polarity for tungsten electrode...
Page 38: ...Remote Controller Potentiometer 2k 10k Foot pedal controller Potentiometer 2k 10k...
Page 39: ...www qineo de...