PARAMETERS SETTING: SPECIAL FUNCTIONS
S1
Press this button to scroll the list of settings to edit.
The acronym relative to the setting to be edited appears on the following displays: D1
The value relative to the selected setting appears on the following displays: D2
E1
Using the encoder, edit the value of the selected setting.
The value is saved automatically.
Press any key (except S1) to save the setting and quit the menu.
Tab. 12 - Special functions in MMA mode
ACRONYM
PARAMETER
MIN DEFAULT MAX
d.Ar.
DYNAMIC ARC oFF
oFF
on
Tab. 13 - SPECIAL FUNCTIONS menu parameters: CONTINUOUS DC TIG mode, PULSED DC TIG mode, SYNERGIC DC TIG mode
ACRONYM
PARAMETER MIN DEFAULT MAX
q.St.
Q-START
0.1 s
oFF
60.0 s
d.Ar.
DYNAMIC ARC 1
oFF
50
M.tA.
MULTI TACK 0.5 Hz
oFF
6.0 Hz *1
Tab. 14 - Special functions in AC TIG and PULSED AC TIG modes
ACRONYM
PARAMETER
MIN
DEFAULT
MAX
M.AC.
MIX AC
10 %
oFF
80 %
E.Fu.
FUSIONE EXTRA
0.0 %
oFF
80 %
F.AC.
AC INVERSION FREQUENCY
20 Hz
65 Hz
200 Hz
bAL
AC BALANCE
-10
0
+10
d.EL.
AC TIG ELECTRODE DIAMETER 1,0 mm
2,4 mm
4,0 mm
*1: When this function is active welding is performed without the following parameters:
SLOPE UP - SLOPE DOWN - START CURRENT - FINAL CURRENT
Summary of Contents for GLW 322
Page 1: ...operating instructions and spare parts GLW 322 Rev 0 EN...
Page 8: ...GLW 322 Cod 006 0001 1861 01 09 2014 v2 0 ENGLISH 7 38 polarity to basic electrode...
Page 10: ...GLW 322 Cod 006 0001 1861 01 09 2014 v2 0 ENGLISH 9 38 polarity for tungsten electrode...
Page 38: ...Remote Controller Potentiometer 2k 10k Foot pedal controller Potentiometer 2k 10k...
Page 39: ...www qineo de...