![Cloos GLW 322 Operating Instructions And Spare Parts Download Page 27](http://html1.mh-extra.com/html/cloos/glw-322/glw-322_operating-instructions-and-spare-parts_2625801027.webp)
Cod.006.0001.1861
01/09/2014 v2.0
ENGLISH
GLW 322
26/38
4.5
PARAMETERS SETTING: (1ST LEVEL)
S2
Press this button to scroll the list of settings to edit.
The acronym relative to the setting to be edited appears on the following displays: D1
The value relative to the selected setting appears on the following displays: D2
E1
Using the encoder, edit the value of the selected setting.
The value is saved automatically.
Press any key (except S2) to save the setting and quit the menu.
Tab. 3 - Parameters of the 1st level menu: MMA mode
ACRONYM
PARAMETER
MIN DEFAULT MAX
-
WELDING CURRENT
MAXIMUM CURRENT WITH REMOTE CONTROLLER
10 A
10 A
300 A *3
Ho.S.
HOT-START
0 %
50%
100 % *1
Ar.F.
ARC FORCE
0 %
30%
250 % *1
S2
Hold down the button for 3 seconds to gain access to the 2nd level menu.
The acronym relative to the setting to be edited appears on the following displays: D1
The value relative to the selected setting appears on the following displays: D2
S2
Press this button to scroll the list of settings to edit.
E1
Using the encoder, edit the value of the selected setting.
The value is saved automatically.
Press any key (except S2) to save the setting and quit the menu.
Tab. 4 - Parameters of the 1st level menu: CONTINUOUS DC TIG mode
ACRONYM
PARAMETER
MIN
DEFAULT
MAX
Pr.G.
PRE-GAS TIME
0.0 s
0.1 s
10.0 s
St.C.
STARTING CURRENT
2 %
5 A
50 %
40 A
200 %
320 A
*2
Sl.u.
SLOPE UP
0.0 s
0.0 s
25.0 s
WELDING CURRENT
MAXIMUM PEDAL CURRENT
5 A
80 A
320 A
*3
S.Cu.
SECOND WELDING CURRENT 10 %
50 %
200 % *1
Sl.d.
DOWN SLOPE
0.0 s
0.0 s
25.0 s
F.Cu.
FINAL CURRENT
5 %
5 A
5 %
5 A
80 %
320 A
*2
Po.G.
POST GAS TIME
0.0 s
10.0 s
25.0 s
Tab. 5 - Parameters of the 1st level menu: PULSED TIG DC mode
ACRONYM
PARAMETER
MIN
DEFAULT
MAX
Pr.G.
PRE-GAS TIME
0.0 s
0.1 s
10.0 s
St.C.
STARTING CURRENT
2 %
5 A
50 %
40 A
200 %
320 A
*2
Sl.u.
SLOPE UP
0.0 s
0.0 s
25.0 s
WELDING CURRENT
MAXIMUM PEDAL CURRENT
5 A
80 A
320 A
*3
S.Cu.
SECOND WELDING CURRENT
10 %
50 %
200 %
*1
b.Cu.
BASE CURRENT
1 %
40 %
200 %
PE.t.
PEAK TIME
1 %
0.1 s
50 %
5.0 s
99 %
5.0 s
*2
P.Fr.
PULSED CURRENT FREQUENCY 0.1 Hz
100 Hz
2.5 KHz
bA.t.
BASE TIME
0.1 s
5.0 s
5.0 s
Sl.d.
DOWN SLOPE
0.0 s
0.0 s
25.0 s
F.Cu.
FINAL CURRENT
5 %
5 A
5 %
5A
80 %
320 A
*2
Po.G.
POST GAS TIME
0.0 s
10.0 s
25.0 s
*1: This parameter is set as a percentage referred to the value of the following parameter:
WELDING CURRENT
*2: The value of this parameter can be set as a percentage of the welding current or as an absolute value expressed in Amperes.
*3: This setting is used to adjust both parameters.
Summary of Contents for GLW 322
Page 1: ...operating instructions and spare parts GLW 322 Rev 0 EN...
Page 8: ...GLW 322 Cod 006 0001 1861 01 09 2014 v2 0 ENGLISH 7 38 polarity to basic electrode...
Page 10: ...GLW 322 Cod 006 0001 1861 01 09 2014 v2 0 ENGLISH 9 38 polarity for tungsten electrode...
Page 38: ...Remote Controller Potentiometer 2k 10k Foot pedal controller Potentiometer 2k 10k...
Page 39: ...www qineo de...