B-8
Operation
GLC 353/503 MC3
B1.2
Operating elements on the wire drive unit
Switch Pulse adaptation
or choke
Push button
Switch With/
Wire manual
without pulse
Push button
Potentiometer 2
Gas manual
Arc length/
(Weld voltage)
Potentiometer 1
Output (wire feed)
During pulse operation the switch 'Pulse adaptation or choke' enables an adaptation of
pulse energy, sometimes required for different cable assembly lengths.
During normal operation this switch 'Pulse adaptation or choke' is used to set the choke
influence.
The table below shows the function of the two Potentiometers, depending on the selected
Procedure.
Procedure
Normal
Normal
Pulse
TIG
Electrode
2 buttons
Synergic
Synergic
Poti. 1
Wire feed
Output
Output
Current
Current
Poti. 2
Weld voltage
Arc length
Arc length
no function
The Switch without/with pulse is active if the procedure Normal-Synergic or Pulse-
Synergic was selected. You can change over from characteristic curve Normal synergic to
Pulse synergic.