This group defines the start and end sentinel for each track. The sentinel is always used to
extract the track data from the whole MSR data string. The data length for each sentinel is
fixed to one character. Because there is ISO standard that defining the start and end sentinel
for the three tracks. For the compatible reason, please do not modify the default value if
possible.
Decode Mode
For this group, it contains two kinds of settings, which are:
Track Data Filtering:
Determine which track to be, not to be output or needed to be
output.
Switch Output Order:
Change the output order of track 1 ~ 3.
Track Data Filtering
Shown below is the filter setting for track 1. This provides a fool-proofing method in case of
receiving unwanted or uncompleted track data.
These three filter settings are:
Enable:
If selected, the data of specified track will be packaged in the MSR data string. If
the specified track data is not decoded, it will leave blank in the MSR data string.
Required:
If selected, which means the output MSR data string must contain the
specified track data. If the specified track data is not decoded, even MSR data string contains
other track data, it will still not to be output.
Disable:
If selected, the data of specified track will not be packaged in the MSR data
string. No matter it is decoded or not.
Summary of Contents for PT6100
Page 1: ...1 1 1 1 P N Cover Page Cover page PT6100 User Manual Version 1 0...
Page 9: ...Clientron PT6100 User Manual Version 1 0 9 111 2 3 Internal Layout...
Page 33: ...Clientron PT6100 User Manual Version 1 0 33 111 8 Click Next 9 Click Next...
Page 50: ...Clientron PT6100 User Manual Version 1 0 50 111...
Page 53: ...Clientron PT6100 User Manual Version 1 0 53 111 6 Click Next 7 Click Next...
Page 54: ...Clientron PT6100 User Manual Version 1 0 54 111 8 Click Install 9 Click Finish...
Page 57: ...Clientron PT6100 User Manual Version 1 0 57 111 14 Select Sample 15 Select VB6...
Page 59: ...Clientron PT6100 User Manual Version 1 0 59 111 18 Select Fingerprint Enrollment...
Page 64: ...Clientron PT6100 User Manual Version 1 0 64 111 1 3 2 Click Next 1 3 3 Click Next...
Page 65: ...Clientron PT6100 User Manual Version 1 0 65 111 1 3 4 Click Giga TMS Next 1 3 5 Click Next...
Page 72: ...Clientron PT6100 User Manual Version 1 0 72 111...
Page 73: ...Clientron PT6100 User Manual Version 1 0 73 111...
Page 74: ...Clientron PT6100 User Manual Version 1 0 74 111...
Page 76: ...Clientron PT6100 User Manual Version 1 0 76 111...
Page 80: ...Clientron PT6100 User Manual Version 1 0 80 111...
Page 81: ...Clientron PT6100 User Manual Version 1 0 81 111...
Page 87: ...Clientron PT6100 User Manual Version 1 0 87 111 3 Run Setup exe 4 Click Yes...
Page 93: ...Clientron PT6100 User Manual Version 1 0 93 111 5 Starting install 6 Click Finish...