background image

© DESIGNA Verkehrsleittechnik GmbH

Subject to technical modification without prior notice

Manual

System PM100

Automatic Pay Station

APS 100 COMPACT

Ticket / CHIPMASTER

Version 1.20

Summary of Contents for AKS 100 COMPACT

Page 1: ... DESIGNA Verkehrsleittechnik GmbH Subject to technical modification without prior notice Manual System PM100 Automatic Pay Station APS 100 COMPACT Ticket CHIPMASTER Version 1 20 ...

Page 2: ......

Page 3: ...ation 21 4 Erection of the pay station 22 4 1 Wall mounting 22 4 2 Erection with stand 23 4 3 Connections of the APS 100 COMPACT 24 4 3 1 Power supply 24 4 3 2 Connection up the intercom 24 4 3 3 DESINET connection 25 5 Initial commissioning 25 5 1 First check of the pay station 25 5 2 Function test 25 6 Maintenance 26 6 1 Daily care and checks 26 6 2 Monthly maintenance 27 6 3 Quarterly maintenan...

Page 4: ...n APS 100 COMPACT page 4 DESIGNA Verkehrsleittechnik GmbH Overview of versions Version 1 0 03 06 1998 JB Eh Compilation of the document Version 1 1 10 03 1999 Ba Revision new housing Version 1 2 30 10 1999 Ba Revision new printer ...

Page 5: ...ion 1 Complete overview of the COMPACT pay station 1 2 Housing The housing is made from elo galvanised sheet steel the door consists of stainless steel The standard version of the unit is powder coated in Pantone 320C turquoise blue Other coatings are possible as options The components required to operate the unit are mounted on a frame In the basic version the pay station is supplied without stan...

Page 6: ...ge the language used in the display The possible lan guages are indicated by the flags next to the button The language texts are downloaded from the BFR by pressing the button and are then shown in the display The system can manage up to 4 languages Optional for ticket systems Lost ticket With this button the customer can request a replacement ticket at a special rate normally the daily rate This ...

Page 7: ... in the rear left hand section of the pay station This switch is used to switch the pay station on and off In the lower position the switch disconnects the pay station from the power mains for all poles When this switch is switched on the pay station is supplied with electricity and the TCC loads its program CAUTION The mains filter terminal strip and optional illumination unit are not disconnecte...

Page 8: ...agnetic card reader The magnetic card reader pulls the tickets and cards in reads the data writes codes the data back on the ticket or card in changed form and then returns the card if required Depending on the design of the Multicon paper tickets can be processed together with plastic cards with middle track and optionally also side track credit cards bank and ec cards The magnetic card reader is...

Page 9: ...ponent TBG I offers the possibility of ticket supply it is present when the pay station has the option lost ticket TBG 1 does not allow for processing of credit cards or value cheques TBG II supports the processing of credit cards value and time cheques It has an integrated ticket filter so that the tickets can either be transported into a ticket store or by changing the filter over collected in a...

Page 10: ...hrsleittechnik GmbH UMSL main circuit board 24 V DC main pcb Illustration 5 flat component UTBG 2 assembling side Illustration 6 flat component UTBG 2 soldering side light barrier bottom light barrier middle Light barrier top endposition flap blade motor2 motor1 Flap ...

Page 11: ...he intake slot and the return device together with the electronic control components The unit has a rotor driven by an actuator which moves the parking chips in the VME and fixes them in front of the programming device Illustration 7 Chipmaster unit flat component side Illustration 8 Chipmaster unit actuator side Slot closure Parking chip guide Sensor Flat component CME Front Mounting plate Actuat...

Page 12: ... R14 R5 D2 D7 R 11 L3 D9 X1 X17 C51 R71 X5 C46 X2 IC10 X15 X16 C30 C29 R36 C43 R45 D4 D5 R17 R35 R34 C 31 R39 R16 R 9 R 7 C 24 D10 R8 C44 D16 D14 D12 R19 D15 C 49 R18 C52 D13 C55 L1 C38 X6 R30 X7 C48 TAST1 R57 R44 D11 X10 R 10 IC8 LED7 F1 C42 T2 R43 R70 R 38 R31 D3 X12 C20 C22 C36 X11 R2 X4 X8 X9 R1 R13 C34 R 21 IC5 R67 IC3 LED1 C28 R4 C25 C 26 R 22 C40 C47 R24 R27 R33 C37 R48 L2 R 20 C19 C27 C39 ...

Page 13: ...AM 1 MB Flash RAM for program 1 MB S RAM for data Data security Integrated Goldcap capacitor for 2 3 days data preservation Optional lithium battery for approx 1 year data preservation Serial interfaces 9x RS 232 including 2 optoelectronic couplers 1x RS 232 for DEBUG 1x RS 485 for the car park network DESINET with integrated connectable final resistance Parallel interface 12 inputs and 12 outputs...

Page 14: ... C TS o p to is ola te d T P J A P P T P P L R T P L IL C L R X T X H A LT P O W E R RESET TCC Addr HIGH TCC Addr LO W sid e u p Battery CR 1620 D E B U G Attenuator ON OFF P H N 24 VDC connection to DESINET internal end resistor for the DESINET switchable power supply 24V DC LED CPU stopped power on RESET button TCC Adress 10 point 1 point DEBUG interface 9pol D SUB male DEBUG interface Western D...

Page 15: ...then sorted into the corresponding hoppers or into the end cassette and the change is paid out from the intermediate store of the pay station The coin tester sends the coins directly to the hoppers via the sorting shaft so that only four different types of coin can be stored in the hoppers It is not possible to allocate one type of coin to two hoppers Coin insert with slot closure Coin tester Sort...

Page 16: ...nd a lateral output channel with optical monitoring The coins are supplied by means of a rotor disk controlled by the printed circuit board of the MVE Various rotor disks and inserts are available for the hoppers depending on the various coin sizes A description of the hoppers is contained in the appendix 1 4 6 5 Coin filter Every inserted and accepted coin is sorted either into the hopper or into...

Page 17: ... to return a note once it has been paid into the end cassette If several notes are to be accepted this is possible by means of a software intermediate store software licence here the notes are taken immediately into the end cassette In the case of cancellation of the payment transaction the value already booked off the ticket is recoded as credit note and subtracted from the park ing fee at the ne...

Page 18: ... no more paper producing a mes sage to the data control centre The paper has DESIGNA Ident number 7 232 120 550 Changing the receipt paper for the thermal printer Open the pay station door Remove the old paper roll place a new roll on the shaft and set it back in the holder Cut the paper off smoothly and at right angles to the rolling direction Thread the paper into the intake slot until you feel ...

Page 19: ...data Feature Data Printing method Thermal printing Resolution 4 dots per mm Dots per line 192 Printing width 48 mm Paper empty indicator light barrier Speed 200 dot lines per sec 55 mm per sec Paper Feed 0 25 mm Power supply 24V Temperature range 0 to 60 C Service life 300 000 cuts 50 million pulses 30 km paper Paper width 58 0 1 mm Paper thickness 50 g Weight approx 330 g Recommended paper FH65BX...

Page 20: ...freeze heating 250W Lighting 36W Temperature Storage 25 to 80 C Operation 20 to 50 C optional ventilation or second heating Noise level 70 dB A Weight approx 150 Kg depending on version Dimensions Height 1900 mm Width 700 mm Depth 500 mm without illumination unit 530 mm with illumination unit Control voltage 24V DC 1 A max Control inputs outputs 0V active 0 5A max ...

Page 21: ...e authorisation to drive out of the car park within the courtesy period period be tween payment and inserting the ticket at the exit is magnetically coded on the ticket The ticket is then returned For pay stations with Chipmaster system the same procedure takes place but without the printing stage Any change to be paid out is provided in the return tray The payment procedure can be interrupted at ...

Page 22: ...the wiring is correct and that the foundation plate has been set The pay station is available in various versions It can be mounted to a wall erected on a stand or base 4 1 Wall mounting Unpack the unit near the erection site to avoid any damage during transport Mark the holes for the frame and drill the holes see drawing Kabelzufuehrung Ausbruch in der Kasse cable feed point leadthrough in the pa...

Page 23: ...ove the transport safeguards for the Multicon parking chip reader and the receipt printer Check the positions of the components to the intake and outlet slots in the door and ad just if necessary 4 2 Erection with stand Illustration 14 Foundation drawing APS 100 COMPACT Reaction plugs must be used for erection without foundation plate Unpack the unit near to the erection site to avoid damage durin...

Page 24: ...coming lines 4 3 1 Power supply The power supply 230V 50Hz single phase is to be kept separate from the sub distribution It is safeguarded by means of 10 16A automatic fuses The lead should consist of cable type NAM 3 5 x1 5mm or a corresponding underground cable with a cross section of min 1 5 mm The wire cross section is to be adjusted to the valid standards for the routed cable length Three fus...

Page 25: ...tory regulations containing electromagnetic compatibility cannot be fulfilled 5 Initial commissioning 5 1 First check of the pay station The installed TCC can have been supplied with a different unit address than that re quired at its actual location or adjusted at the data control centre In this case the unit will not go ONLINE In this case the unit address of the TCC must be adjusted To do so sw...

Page 26: ... the heating switches on As soon as the heating produces warmth reset the thermostat to its original position If a second person is there you can check the function of the intercom Press the informa tion button at the APS A signal must sound in the data control centre Then check the voice transfer Check that the coin slot works easily Check the roll of paper in the receipt printer If you can see t...

Page 27: ... and a mild cleaning agent If neces sary vacuum clean the unit from the inside vacuum clean the mounting plate carefully Clean the display with a soft cloth and glass cleaner For ticket systems Clean the transport rollers of the magnetic card reader with isopropyl alcohol or spirit and a lint free cloth If present apply a little resin free oil to the blade and eccentric unit of the transport compo...

Page 28: ...he ribbon cassette upwards to do so push the holder up and remove the cassette Illustration 15 ticket printer Insert the new ribbon cassette ensuring that the ribbon is guided between knob and sheet metal as shown and runs around the metal pin The ribbon cassette should engage firmly in position Then tighten the ribbon with the knob Finally replace the printer in its guide Holder Knob Metal pin ...

Page 29: ...ccounting per list or by means of data carrier exchange with the bank software licence 7 1 3 Electronic purse optional If a reader for the electronic purse is integrated at the automatic or manual pay station then the customer can pay for his ticket with the money card 7 1 4 Discounting ticket punch discounter optional Short term parking tickets can be discounted in various ways by punching a disc...

Page 30: ... to connect up a voice synthesiser The voice synthesiser can be used to give the user special instructions by acoustic text messages which would not be possible without lan guage synthesiser When a certain action is carried out at the automatic pay station the synthesiser receives a pulse and produces the specified text file ...

Page 31: ...to the coin output window can be replaced resulting in ten different possible combinations for processing common coins Before replacing the coin disk first the hopper should be emptied e g with function card chip empty tubes and then jackpot To replace the rotor disks first raise the coin channel To do so unscrew the knurled screw raise the coin guide rail and screw tight again then unhinge the co...