Shown below is the data structure of the output string for MSR.
PP PR1
SS1
TK1
ES1
SU1
PR2
SS2
TK2
ES2
SU2 PR3
SS3
TK3
ES3
SU3
SU
DM
PP:
Prefix for package.
PR1:
Prefix for track 1.
SS1:
Start sentinel for track 1.
TK1:
Data for track 1, if error happens, using Error Message instead.
ES1:
End sentinel for track 1.
SU1:
Suffix for track 1.
PR2:
Prefix for track 2.
SS2:
Start sentinel for track 2.
TK2:
Data for track 2, if error happens, using Error Message instead.
ES2:
End sentinel for track 2.
SU2:
Suffix for track 2.
PR3:
Prefix for track 3.
SS3:
Start sentinel for track 3.
TK3:
Data for track 3, if error happens, using Error Message instead..
ES3:
End sentinel for track 3.
SU3:
Suffix for track 3.
SU:
Suffix for package.
DM:
Delimiter for the swipe result.
Prefix/Suffix
In default, the prefix and suffix settings are all keep blank. There are 4 kinds of prefix and suffix
to be defined, which are:
Package:
For the prefix string, it is appended in the front of the whole MSR data. For the
suffix, it is appended in the end of the whole MSR data. In most case, the suffix for package is
always to be the “Enter” or “Tab” character. The max data length of the prefix and suffix for the
package can be up to 127.
TK1:
For the prefix string, it is appended in the front of the start sentinel of track 2. For
the suffix, it is appended in the end of the end sentinel of track 2. The max data length of the
prefix and suffix for the TK1 can be up to 127.
TK2:
For the prefix string, it is appended in the front of the start sentinel of track 2. For
the suffix, it is appended in the end of the end sentinel of track 2. The max data length of the
prefix and suffix for the TK1 can be up to 127.
TK3:
For the prefix string, it is appended in the front of the start sentinel of track 3. For
the suffix, it is appended in the end of the end sentinel of track 3. The max data length of the
prefix and suffix for the TK1 can be up to 127.
Summary of Contents for PT6300
Page 1: ...1 95 PT6300 User Manual Version 2 0 P N Cover page ...
Page 5: ...ClientPOS PT6300 User Manual Version 2 0 5 95 7 5 Save Exit 8 LCD Surface Cleaning P93 P94 ...
Page 9: ...ClientPOS PT6300 User Manual Version 2 0 9 95 2 3 Internal Layout ...
Page 33: ...ClientPOS PT6300 User Manual Version 2 0 33 95 8 Click Next 9 Click Next ...
Page 42: ...ClientPOS PT6300 User Manual Version 2 0 42 95 3 Run Setup exe 4 Click Next ...
Page 44: ...ClientPOS PT6300 User Manual Version 2 0 44 95 7 Click Next 8 Click Install ...
Page 45: ...ClientPOS PT6300 User Manual Version 2 0 45 95 9 Click Finish 10 Restart systems ...
Page 47: ...ClientPOS PT6300 User Manual Version 2 0 47 95 13 Select COM ActiveX 14 Select Samples ...
Page 48: ...ClientPOS PT6300 User Manual Version 2 0 48 95 15 Select VB6 16 Select Enrollment Sample ...
Page 55: ...ClientPOS PT6300 User Manual Version 2 0 55 95 1 3 2 Click Next 1 3 3 Click Next ...
Page 56: ...ClientPOS PT6300 User Manual Version 2 0 56 95 1 3 4 Click Giga TMS Next 1 3 5 Click Next ...
Page 63: ...ClientPOS PT6300 User Manual Version 2 0 63 95 ...
Page 64: ...ClientPOS PT6300 User Manual Version 2 0 64 95 ...
Page 65: ...ClientPOS PT6300 User Manual Version 2 0 65 95 ...
Page 70: ...ClientPOS PT6300 User Manual Version 2 0 70 95 3 Run Setup exe 4 Click Yes ...