background image

 

APOLLO LOW PRESSURE SUPPLIED-AIR RESPIRATOR 

Page 14 

HELMET MODEL 20 

 

 

 

 

 

© 2011 CLEMCO INDUSTRIES CORP.  

  

www.clemcoindustries.com

  

  Manual No. 21991

 

9.6.2.9

 Make sure the chin strap is in place, then 

reattach the cape to the helmet by following the 
instructions in Section 9.5. 

 
 
9.7 Chin 

Strap 

 

9.7.1 

Replace the chin strap when worn or when it 

loses its elasticity. 

 
 
9.8 

Removing and Replacing the Air Channel 

Partition 

 

9.8.1

 

Remove the cape and suspension per Sections 

9.5 and 9.6. 
 

9.8.2 

Pull the partition from the front to unsnap it from 

the retainers. Remove the back end of the partition from 
the tabs. 
 

9.8.3 

Place a new partition into the hood; insert the 

slots on the back end of the partition behind the tabs. 
 

9.8.4

  While applying pressure on the front of the 

partition, work from the back toward the front and snap it 
into place. 
 

9.8.5 

Replace the suspension and cape. 

 

 
 

10.0 REPLACEMENT 

PARTS 

 

 

WARNING 

Use of any non-Clemco replacements parts may 
permit ingress of hazardous contaminants, and 
may cause injury, disease, or death to the user. 
OSHA Regulation 29 CFR 1910.134(H)(4)(i) 
requires the use of the respirator 
manufacturer’s NIOSH-approved parts 
designated for the respirator. Using any parts 
listed in this section made by any manufacturer 
other than Clemco voids the NIOSH approval, 
and voids Clemco’s warranty. 

 
 
10.1 

Supplied-Air Respirator Systems and 

 Alternate 

Accessories 

 

Respirator Systems 

 

Description Stock 

No. 

 

Apollo 20 LP

 

Supplied-Air Respirator with Standard 

DLX Padded Suspension 

 

less respirator hose........................................... 25292 
with 50-foot respirator hose .............................. 25293 

 
 

Accessories 

 

Description Stock 

No. 

 

Constant-flow connector, LP with belt  .................... 21777 

 

Pressure conversion kit, LP to HP 

Converts Apollo 20 LP, low pressure 
(ambient air) respirator to high pressure  
(Grade “D” Compressed Air) respirator ................ 22690 

 

DLX padded suspension kit 

Includes everything needed to replace padded 
suspension, or to convert from web suspension 
to DLX padded suspension  ............................... 25215 

 

Hearing protection muffs,  
  Low profile noise reduction muffs  
  for use with web suspension w/sweatband only. 
  May not work with all head sizes  ....................... 23886 

 

Do-rag, washable head scarf  ................................. 23814 

 

CMS-3 CO monitor package ................................... 24612 
 

Summary of Contents for APOLLO 20

Page 1: ...sed instructions Electronic files include a Preface containing the same important information as the orange cover 2011 CLEMCO INDUSTRIES CORP One Cable Car Dr Washington MO 63090 Phone 636 239 4300 Fa...

Page 2: ...th your employer about training programs and materials that are available Our company is proud to provide a variety of products to the abrasive blasting industry and we have confidence that the profes...

Page 3: ...ers are NOT compatible with Clemco equipment If controls are altered involuntary activation which may cause serious injury can occur Inspect the air control orifice DAILY for cleanliness NEVER use wel...

Page 4: ...ct to products used other than in accordance hereunder 2 On products seller manufactures seller warrants that all products are to be free from defects in workmanship and materials for a period of one...

Page 5: ...ice Lines MUST be run AS STRAIGHT AS POSSIBLE from machine to work area with NO sharp bends Check DAILY for internal wear and external damage 9 HOSE COUPLINGS NOZZLE HOLDERS fitted SNUGLY to hose end...

Page 6: ...y alert symbol It is used to alert the user of this equipment of potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death CAUTION Caution us...

Page 7: ...debilitating lung blood liver kidney and skin injuries and even death Toxic dust is produced primarily by the breakdown of the abrasive being used and the surface being treated during abrasive blasti...

Page 8: ...or and found to be safe to breathe Toxic dust poisoning also may occur by eating drinking or smoking in a contaminated area or by eating drinking or smoking in a non hazardous area before thorough was...

Page 9: ...e validated third party testing for use up to 1000 APF In order not to be in violation of OSHA 1000 APF the end user must have a copy of this validated testing A copy of Clemco validated testing may b...

Page 10: ...ith an inner lens that is secured by the window gasket To protect the inner lens a middle lens and up to three perforated cover lenses are securely held in position by the lens gasket and frame 3 2 2...

Page 11: ...n 3 4 1 Respirator hose must be NIOSH approved Clemco 1 2 ID respirator hose 3 4 2 If longer hose is required it must be a NIOSH approved Clemco 1 2 respirator hose extension Use 50 foot or 100 foot C...

Page 12: ...i 4 1 3 Limiting characteristics of Grade D air at the time of publication of this manual are as follows Carbon Dioxide maximum of 1000 ppm Carbon Monoxide maximum of 10 ppm Odor No pronounced odor O...

Page 13: ...spirator hose air entry ports and fittings of all dust and debris Inspect the helmet suspension and if necessary replace it per Section 9 6 5 2 Begin the operation of the ambient air pump per the manu...

Page 14: ...headband slots Slide the headband tongue in or out of the guide to attain the desired head size It is important that the adjustment be made evenly on both sides Press the selected slots firmly onto t...

Page 15: ...service adjusted repaired or discarded in accordance with the following procedures 7 4 2 Adjustments and repairs must be made only by appropriately trained persons and only with genuine Clemco NIOSH...

Page 16: ...dditional disinfecting may be done before and or after use by wiping the surfaces with a commercial disinfecting wipe or spray 9 0 SERVICE MAINTENANCE CAUTION To prevent recontamination of the respira...

Page 17: ...the flange Working from inside the helmet push the gasket toward the tab until the tab is fully inserted into the retaining slot 9 2 8 Repeat the process on the opposite side The gasket must be pushed...

Page 18: ...on web under the chin strap and then secure the suspension by inserting the plastic tabs into their respective mounts the yellow tabs go on the side mounts 9 6 1 7 Align the middle pad so the elastic...

Page 19: ...s contaminants and may cause injury disease or death to the user OSHA Regulation 29 CFR 1910 134 H 4 i requires the use of the respirator manufacturer s NIOSH approved parts designated for the respira...

Page 20: ...ar 21301 13 O Ring 7 8 OD 2 required 22815 14 Breathing tube assembly includes two of item 13 22811 15 Constant flow connector LP w o belt 21429 16 Belt 2 web with buckle 04430 17 Nut lens frame 2 req...

Reviews: