20
P2291BA | 2020-05
Apex Tool Group
9
EN
9
LCD display
The LCD display on the tool is divided into the result dis-
play, status display, operating menu and system error mes-
sages.
9.1 Result display
First line – result:
The status is displayed in alternation with the Application
being used.
9.2 Status display
The status display is divided into the "Standard" and "Link-
ing" modes. "Standard" is selected if "Linking" is not
enabled at the control system.
See
Navigator > Advanced > Linking
. The application
is selected at the <Run Screen> or via the
Application
Select
inputs.
The LCD display consists of a three
lines, each with 6 characters,
to display the status, torque and angle.
The result display is updated after the
rundown ends.
OK
Result is OK
NOK
Result is not OK
OFF
Torque encoder offset error
CAL
Torque encoder calibration error
ENC
Angle encoder error
IP
Current overload in output section
IIT
Requested motor output is too high
TMAX
Maximum fastening time exceeded
RC
Rundown terminated by disabled start signal
Tq<
Torque too low
Tq>
Torque too high
WI<
Angle too small
WI>
Angle too large
Error
Error occurred
AW<
Too few graphic values recorded for an evalu-
ation (SEQ 31/51)
BLOC
Fastened to block / tightened screw fastened
(SEQ 31/51)
IRED
Current redundancy error
JMP
Bit jump detected
MBO>
Torque has exceeded top evaluation torque
(SEQ 31/51)
MBU<
Torque has fallen below bottom evaluation
torque (SEQ 31/51)
MDSI
Safety torque exceeded (SEQ 31/51)
SS>
Time for stick-slip too large
SST
Too many stick-slip edges
TTT<
Time since TT too small
TTT>
Time since TT too large
Second line – Shut-off torque in Nm:
T
Shutoff torque
Third line – Shut-off angle in degrees:
A
Shutoff angle
OK
T12.00
A100
The
symbol at the top right shows an
interrupted data connection to the
control.
No other status messages take priority.
The tool is ready.
Number of remaining rundowns that can
still be carried out until the rundown data
memory is full and the rundown data
have to be transmitted to the control.
All fastening sequences have been
completed.
Synchronize the tool with the control
once again.
No fastening sequences have been ini-
tialized.
Synchronize the tool with the control
once again.
No fastening sequence parameters
have been set.
Check the Application and Tighten-
ing group selected on the control to
determine whether the tool settings
and process programming have
been carried out.
Application locked.
Synchronize the tool with the control
once again.
OK
T12.00
A100
Ready
Remain
512
Job
comple
Sync
No
Job
Sync
Parame
not
set
App
locked
Sync