1. Run provided 1⁄4-inch tubing from the Manifold injection port to
the straight barb fitting. Length of tube should be less than 10 feet.
Shorten and cut tubing as possible. See Figure 10.
2. If the unit is installed below the water line, install a loop in the 1⁄4-
inch line known as a Hartford loop. Loop the Air Tubing so that at
some point, tubing is above water level.
3. Install 1⁄4-inch one-way Air Check Valve (supplied) to eliminate any
potential water back flow. See Figure 10 and 11 for details.
4. Gas exiting the Clear Comfort system to the Venturi connector port
should flow easily.
5. Measure air suction using an Air Flow Meter and set Venturi air
suction to draw between 5 - 7 LPM. See page 16 for detailed
instructions.
CONNECTING CLEAR COMFORT SYSTEM TO MANIFOLD VENTURI
Figure 12: Hartford Loop
Figure 13: Manifold’s 3-Way Valve
INSTALLING THE CLEAR COMFORT
MANIFOLD INJECTION