3. Reverse 3-Way Valve (If Needed)
• Arrange 3-way valve by removing all three unions, as seen below.
• Once you have the 3-way valve facing the correct direction,
connect the it to the Manifold by attaching all three unions.
4. Connect to Pool Plumbing
Put the Manifold into the 11” cut section of the pool plumbing.
5. Position 3-Way Valve
• Position the 3-way valve handle in between
the Venturi & water out flow, as highlighted
in Figure 9.
• Make adjustments, as necessary to set
Venturi air suction to draw between
5 - 7 LPM using a Flow Meter. See
page 16 for detailed instructions.
NOTE:
Failure to properly position the 3-way
valve can result in an unwanted back-flow of
water into the Clear Comfort system and other
negative effects.
INSTALLING THE CLEAR COMFORT
MANIFOLD INJECTION
Figure 7: Manifold Reverse
Figure 8: Connecting Manifold
Figure 9: 3-Way Valve