background image

200

Summary of Contents for iCleaner-200

Page 1: ...200 ...

Page 2: ...ance of thunder storm to avoid personal injury Users are only permitted to perform maintenance described in this manual Any tampering with the Motor Box or Power Supply will void the warranty Ensure the iCleaner 200 is fully submerged before turning the power box on If the iCleaner 200 is not going be used for a long time make sure to disconnect the power keep it clean and put it in a safe dry and...

Page 3: ...r box must be turned of manually Manual cleaning the Remote Control can be used to clean specific areas immediately Self protection out of water Impeller decelerates to a stop in twenty five seconds if the iCleaner 200 senses it is no longer in water to prevent personal injury and to protect the water pump Stop protection the iCleaner 200 will stop if foreign matter retards the Impeller 2 2 Produc...

Page 4: ...2 3 Parts List Main Body Parts Guide Vane Pic 2 3 2 3 Drive Belt Water Joint Filter Net water retaining board Base Plate Support Frame Filter Bag Base Plate Latch Motor Box ...

Page 5: ... Power Box Parts 4 ...

Page 6: ... Filter Bag Pic 3 2 1 5 1 1 1 1 1 1 1 1 1 2 3 4 5 6 7 8 3 Packing List Part Name Unit Body Power Box Remote Control Battery Guide Vane User Manual Warranty Card Certificate of Quality Serial Number Remarks Host Quantity I 10 11 Spare Parts ...

Page 7: ...connect the Power Box to an outside AC power of 100v 240v 50 60Hz see Pic 4 1 2 For the complete connection guide please refer Pic 4 1 3 Notices Do not allow the Power Box to come in contact with water Please ensure the Power Box is Kept in a shady dry ventilated area Refer Page 1 Safety Warning Pic 4 1 1 Pic 4 1 2 6 Unit Body ...

Page 8: ... iCleaner 200 in the water So it will automatically sink to the bottom of pool 2 Start Press the ON button LED POWER indicator And 0 5H cycle time LED will illuminate see pic 4 2 2 You may select 0 5Hr 1Hr or 2Hrs cleaning time using the button on the Remote Control and relative L E D i n d i c a t o r s w i l l illuminate on the Power Box when selected Pic 4 2 1 Pic 4 2 2 7 ...

Page 9: ...iCleaner 200 Invert the iCleaner 200 gently onto the floor unlock the Latch on the Base Plate Pic4 3 2 and remove the Filter Bag from Base Plate clean the Filter Bag Pic 4 3 3 once clean place the Filter Bag on its frame reassemble the Base Plate and put it back into the iCleaner 200 once the Filter Bag is dry Note When re fitting the Filter Bag to the Base Plate please ensure the long sides of th...

Page 10: ...9 Pic 4 4 1 Floor Only Cleaning The Remote Control Pic 4 4 1 includes On Off Power Button LED Light Indicator Direction Button Timer Button Floor Only Cleaning On Off Power Button Turn on or Turn off iCleaner 200 Direction Button Control iCleaner 200 s movement Backward Left Rotation and Right Rotation Timer Button Select the timing mode from 0 5hour 1 hour and 2hours Floor Only Cleaning To clean ...

Page 11: ...4 5 Water Joint 10 Step 2 Screw down the Lock Nut clockwise Pic 4 5 2 Pic 4 5 2 Step 1 Insert water joint into Icleaner 200 Pic 4 5 1 ...

Page 12: ...r damage Step 1 Rotate Guide Vane clockwise to remove from the iCleaner 200 Pic 5 1 1 Step 2 Use a Phillips head screw driver to remove the bolt in the Impeller according the diagram Pic 5 1 2 Step 3 Replace the new Impeller and assemble Impeller and Guide Vane 11 Guide Vane ...

Page 13: ...ey are badly worn or broken Step 1 Invert the iCleaner 200 on the floor remove the Base Plate Push latch to u n l o c k t h e B a s e Plate Pic 5 2 1 Step 2 Remove the Filter Net from the iCleaner 200 while pressing the Latch according to the diagram Pic 5 2 2 12 Pic 5 2 2 ...

Page 14: ...rush Pic 5 2 4 13 Pic 5 2 3 Pic 5 2 4 Transmission Components Side cover Rolling Brush Step 3 Using a Phillips head screwdriver and 7mm ring spannerundo the six bolts and nuts on the Side Cover to remove the Side Cover Pic 5 2 3 ...

Page 15: ...Step 6 Assemble the Rolling Brush to the axle Pic 5 2 6 Step 5 Slide the old sponge wheels off and replace w i t h n e w s p o n g e wheels Pic 5 2 5 Pic 5 2 5 14 wheel axle ...

Page 16: ...f the unit using the nuts and bolts Pic 5 2 8 Step 9 Put the Filter Net into the iCleaner 200 press down on the filter net until the Latch locks into the bracket the filter until the Latch locks into the bracket Pic 5 2 9 Pic 5 2 9 Step 10 Place the base Plate into iCleaner 200 pressing down until the latches lock into place Pic 5 2 10 Replacing the Sponge Wheels is now completed Pic 5 2 10 ...

Page 17: ... water retainining board to one end remove the water retainining board carefully Step 2 Insert one end of the water retaining board into the locating holes on the base plate then insert the other end of the water retaining board into the base plate and make sure the water retaining board does not have a bend in it if it does gently push the hinged edge until it clicks into position Note The water ...

Page 18: ...ide the machine Belt of Filter Bag is loosen or broken Dirt is too fine for the filter bag Plug in the power lead Check the connection clean the Impeller Replace the Impeller clean the Filter Bag replace the drive Belt Clean Filter Bag clean the Filter Bag replace the Drive Belt Replace the Sponge wheel replace axis sleeves Wobble iCleaner 200 and make sure air released Replace broken filter bag P...

Page 19: ...rload 1 Check whether water pump motor and impeller about exceptions Indicator light Solution Failure Green light flashing The iCleaner has stopped due to lack of water Return the robot to deeper water and restart Yellow light flashing The Motor Pump inside the robot has over heated Contact the supplier for support Blue light flashing The robot is upside down Turn the iCleaner over and restart usi...

Page 20: ...wer Box is turned off and store it in a dry shady well ventilated area with a temperature range between 0 40 If you want to reuse iCleaner 200 after it has been stored for an extended period of time please check the iCleaner 200 for visual damage cracks rust prior to use Once you are sure iCleaner 200 is free from damage test run it and if it performs as expected then allow it to run automatically...