303.872.4477 [email protected] clearcomfort.com
17
OPERATING INSTRUCTIONS
1. Install plumbing according to Figure 4.
2. Ensure the Manifold’s 3-way valve is OPEN before turning pumps ON.
3. Turn pool/spa pump and filtration systems on.
4. Position the Manifold’s 3- Way Valve
• Position the 3-way valve handle in between the Venturi & water out
flow, as highlighted in Figure 9.
• Make adjustments, as necessary to set Venturi air suction to draw
between 5 - 7 LPM using a Flow Meter. See page 16 for
detailed instructions.
5. Toggle Clear Comfort system switch to the ON position.
6. Water entering the pool/spa should have bubbles exiting from at least
one of the returns on to the body of water.
INSTALLING THE CLEAR COMFORT
MANIFOLD INJECTION
Summary of Contents for CCW100
Page 27: ......