background image

Introduction

GP - Series | Version 1.03

3

1

Introduction

You have made a good choice by purchasing the 
CLEANCRAFT garden pump. 

Read the operating manual thoroughly before com

-

missioning the machine.  

It gives you information about the proper commission-
ing, intended use and safe and efficient operation and 
maintenance of your water pump. 

The operating manual is part of the water pump pac-
kage. Always keep this operating manual in the location 
where your garden pump is being operated. All local ac

-

cident prevention regulations and general safety instruc

-

tions for the operating range of your garden pump must 
also be complied with. 

1.1 Urheberrecht

The contents of these instructions are copyright. They 
may be used in conjunction with the operation of the gar

-

den pump. Any application beyond those des-cribed is 
not permitted without the written approval of Stürmer Ma

-

schinen GmbH. 

For the protection of our products, we shall register tra-
demark, patent and design rights, as this is possible in 
individual cases. We strongly oppose any infringement 
of our intellectual property.

1.2 Customer service

Please contact your dealer if you have questions con-
cerning your garden pump or if you need technical ad

-

vice. They will help you with specialist information and 
expert advice. 

Germany:

Stürmer Maschinen GmbH 
Dr.-Robert-Pfleger-Str. 26 
D-96103 Hallstadt 

Repair service:

Fax: 

0049 (0) 951 96555-111 

E-Mail: 

[email protected]

Internet: 

www.cleancraft.de

Spare part orders:

Fax: 0049 (0) 951 96555-119 
E-Mail: [email protected]

We are always interested in valuable experience and 
knowledge gained from using the application-which then 
could be shared and be valuable to develop our products 
even further.      

1.3 Limitation of liability

All information and notes in these operating instructions 
were summarised while taking applicable standards and 
rules, the state-of-the-art technology and our long-term 
knowledge and experiences into consideration. 

In the following cases the manufacturer is not liable for 
damages: 

- Non-observance of the operating instructions,

- Inappropriate use,

- Use of untrained staff,

- Unauthorised modifications,

- Technical changes,

- Use of not allowed spare parts. 

The actual scope of delivery may deviate from the ex-
planations and presentations described here in case of 
special models, when using additional ordering options 
or due to latest technical modifications. 

The obligations agreed in the delivery contract, the ge-
neral terms and conditions as well as the delivery condi-
tions of the manufacturer and the legal regulations at the 
time of the conclusion of the contract are applicable. 

2

Safety

This section provides an overview of all important safety 
packages for the protection of operating personnel as 
well as for safe and fault-free operation. Other task-ba

-

sed safety notes are included in the paragraphs of the in

-

dividual phases of life.

2.1 Symbol explanation

Safety instructions

The safety notes in these operating instructions are high-
lighted by symbols. The safety notes are intro-duced by 
signal words which express the concern of the risk. 

DANGER!

This combination of symbol and signal words indica-
tes an imminently dangerous situation which may 
lead to death or severe injury if not avoided. 

WARNING! 

This combination of symbol and signal words indica-
tes a potentially dangerous situation which may lead 
to death or severe injury if not avoided. 

Summary of Contents for 7521100

Page 1: ...W ATER P UMP Garden Pump GP 1105 S Operating Instructions GP 1105 C GP 1105 S GP 1105 P GP 1306 S GP 1105 P GP 1306 S GP 1105 C...

Page 2: ...rating company 4 2 3 Requirements to staff 5 2 4 Personal protective equipment 5 2 5 General safety regulations 5 2 6 Safety labels on the water pump 7 3 Intended use 7 3 1 Improper use 7 3 2 Residual...

Page 3: ...dge gained from using the application which then could be shared and be valuable to develop our products even further 1 3 Limitation of liability All information and notes in these operating instructi...

Page 4: ...correspond to the current status of the regulations and must ad apt these if necessary The operating company must unambiguously regu late and determine the responsibilities for installa tion operation...

Page 5: ...o protect per sons against impairments of safety and health while wor king The staff member has to wear personal protec tive equipment while performing different tasks on and with the machine which ar...

Page 6: ...ot used for a long time drain the piping system to prevent ice from forming in the pump chamber ATTENTION Store the device taking into account its weight viz on a firm level surface and only in a clos...

Page 7: ...ne is put to its intended use there are still residual risks which are listed below Risk of injury of upper and lower limbs while equip ment is operating Heat build up on components can cause burns an...

Page 8: ...8 m 8 m Engine speed 2850 min 2850 min Engine power 1100 W 1100 W Cooling Air cooling Air cooling Sound pressure level 82 dB 84 dB Running time at 75 load 4000 Std 4000 Std Length of cable 1 5 m 1 5...

Page 9: ...ms may be parked on it Step 1 Turn off the water pump and drain completely Wipe all accessible surfaces and let the water pump dry Step 2 Disconnect the suction and discharge lines from the pump and s...

Page 10: ...ording to the current water level in the water tank Display functions GP 1105 S Fig 7 Display functions GP 1105 S The water pump GP 1105 S has a LCD display with two buttons SET and CHECK which makes...

Page 11: ...can cause damage When laying the connecting cables make sure that no weight vibrations or tensions are applied to the pump In addition the connecting cables must not be damaged or have a counterfall t...

Page 12: ...ne person Other persons must keep away from the water pump during operation ATTENTION Make sure that only fresh water is pumped with the water pump Using the water pump for other fluids will damage th...

Page 13: ...that are not resistant to internal pressure may cause the pres sure line to burst during operation This may cause injury due to liquid escaping from the line DANGER Danger to life due to electric shoc...

Page 14: ...d with water If this venting is omitted the pump does not suck in the pumped liquid It is recom mended but not necessary in addition to deaerate the suction line or to fill it with water ATTENTION Dry...

Page 15: ...ce For any trans port the pump must be disconnected from the mains The pump must be completely emptied and stored in a frost proof condition Only a regularly maintained and well maintained device can...

Page 16: ...are available from the manufacturer of the lubricants If necessary request the product specific data sheets 13 Disturbances possible causes and measures ATTENTION If one of the following errors occurs...

Page 17: ...nozzle in take manifold suction hose or filter 1 Remove blockages 2 Clean or change the filter 3 Insert the filter cover correctly 4 Check correct installation position of the filter Pump is not runni...

Page 18: ...an for the water pump GP 1105 C must be ordered The fan wheel has the number 35 in the spare part dra wing Type of device Garden pump GP 1105 C Item number 7521100 Position number 35 The order number...

Page 19: ...re Parts Drawing GP 1105 C In case of the service the following drawing shall help to identify the necessary spare parts If necessary send a copy of the parts drawing with the marked components to you...

Page 20: ...20 GP Series Version 1 03 Spare Parts 14 3 Spare Parts Drawing GP 1105 P Fig 11 Spare Parts Drawing GP 1105 P 14 4 Spare Parts Drawing GP 1105 S Fig 12 Spare Parts Drawing GP 1105 S...

Page 21: ...Spare Parts GP Series Version 1 03 21 14 5 Spare Parts Drawing GP 1306 S Fig 13 Spare Parts Drawing GP 1306 S...

Page 22: ...22 GP Series Version 1 03 Wiring Diagrams 15 Wiring Diagrams GP 1105 S Fig 14 Wiring Diagram GP 1105 S GP 1306 S 1105 P und 1105 C Fig 15 Wiring Diagram GP 1306 S 1105 P and 1105 C...

Page 23: ...DIN EN 60335 1 2012 Household and similar electrical appliances Safety Part 1 General requirements DIN EN 60335 2 41 Household and similar electrical appliances Safety Part 2 41 Particular requirement...

Page 24: ...www cleancraft de...