Installation
GP - Series | Version 1.03
11
Automatic function:
During normal operation of the water pump, the LCD dis
-
play will show either „Pressure“ or „Flow“. As soon as the
water supply is closed and no more water flows, the
pump switches off. The display shows "OFF" but the
pump remains in standby mode. As soon as the water
supply is opened, the pressure sinks and the pump swit
-
ches itself on again.
Timer function:
It is possible to set the switch-on and switch-off time of
the pump. By briefly pressing the "SET" button, you
switch to the menu to set the time. In the menu you can
set hours and minutes by pressing the "CHECK" button..
Function GP 1306 S
The water pump is programmed to automatically control
all pumping operations. Some malfunctions can be de
-
tected by the pump. Insufficient water supply and
blocked inlet. In this case, the pump stops to avoid pump
damage due to dry running. Restart the device by press
-
ing the Reset button after the fault has been rectified.
8
Installation
8.1 Notes for installation
Fig. 8: Setting up the pump GP 1306 S
All connection lines must be absolutely leak-tight, as lea
-
king lines can impair the performance of the pump and
cause considerable damage. It is therefore essential to
seal the threaded parts of the cables with each other and
the connection to the pump with Teflon tape. Only the
use of sealing material such as Teflon tape ensures that
the assembly is airtight. Avoid excessive force when
tightening fittings, which can cause damage.
When laying the connecting cables, make sure that no
weight, vibrations or tensions are applied to the pump. In
addition, the connecting cables must not be damaged or
have a counterfall to the pump.
8.2 Electrical connection
The device has a mains connection cable with mains
plug. Power supply cables and power plugs may only be
replaced by qualified personnel in order to avoid ha
-
zards. Do not lift or carry the pump by the power cord,
and do not use it to disconnect the power plug from the
outlet. Protect the power plug and power cord from heat,
oil and sharp edges, and do not use the pump in a humid
environment
.
NOTE!
If the pump switches on more than 6 times within 2
minutes, the pump stops and the display shows
"Error". After one hour the pump starts again and
checks the pump for leaks. 3 cycles run to check
whether the pump is switched on and off a further 6
times within 2 minutes. If this is the case, the pump
switches off completely and "ERROR" appears in the
display.
NOTE!
Before the first operation, the supply line must be
completely filled with water and installed with a bot
-
tom valve.
ATTENTION!
The pump must be set up in a dry place, with the
ambient temperature not exceeding 40 ° C and not
less than 5 ° C. The pump and the entire connection
system must be protected against frost and weather.
ATTENTION!
When installing the unit, make sure that the motor is
adequately ventilated.
NOTE!
When operating the pump outdoors, the electrical
connections must be splash-proof. The connections
must not come into contact with water.
ATTENTION!
The electrical connection must be equipped with a
high sensitive fault-current circuit breaker (RCCB):
30 mA.