background image

Safety

GP - Series | Version 1.03

5

2.3 Requirements to staff

The different tasks described in this manual represent 
different requirements to the qualification of the persons 
entrusted with these tasks. 

Only persons reliable working procedures can be ex-
pected from, are allowed to perform all works. Persons 
the responsiveness of which is affected by e. g. drugs, 
alcohol or medication, are not allowed to work with the 
machine.

The qualifications of the personnel for the different tasks 
are mentioned below:

Operator

The operator is instructed by the operating company 
about the assigned tasks and possible risks in case of 
improper behaviour. Any tasks which need to be per-for

-

med beyond the operation in the standard mode must 
only be performed by the operator if it is indicated in 
these instructions and if the operating company expres

-

sively commissioned the operator.

Electrically qualified person

Electrically qualified person is due to their professional 
training, knowledge and experience as well as knowl-
edge of the relevant standards and regulations, in a po-
sition to carry out work on the electrical systems and to 
independently recognize and avoid possible dangers.

Qualified personnel

Due to their professional training, knowledge and expe-
rience as well as their knowledge of relevant regulations 
the specialist staff is able to perform the assigned tasks 
and to recognise and avoid any possible dangers them-
selves.

Manufacturer

Certain works may only be performed by specialist per-
sonnel of the manufacturer. Other personnel is not au-
thorized to perform these works. Please contact our cus-
tomer service for the execution of all arising work.

2.4 Personal protective equipment

The personal protective equipment serves to protect per-
sons against impairments of safety and health while wor

-

king. The staff member has to wear personal protec-tive 
equipment while performing different tasks on and with 
the machine which are indicated in the individual para

-

graphs of these instructions.

The personal protective equipment is explained in the 

following paragraph

:

2.5  General safety regulations 

Please note the following: 

- Use the guards and secure them securely. Never work 

without guards and get them working.

- Always keep the water pump and working environment 

clean. Ensure adequate lighting and ventilation.

- The water pump may not be modified in its design and 

may not be used for purposes other than those fore

-

seen by the manufacturer.

- Never work under the influence of concentration-distur

-

bing illnesses, fatigue, drugs, alcohol or medicines.

- Only start the water pump as soon as the pump cham

-

ber has filled with water.

- Keep children and not with the water pump Familiar 

people away from their working environment.

- Do not pull on the mains lead to pull the plug out of the 

socket. Protect the cable from heat, oil and sharp 
edges.

WARNING!

Danger in case of insufficient quali

-

fication of the staff!

Insufficiently qualified persons cannot estimate the 
risks while using the House water system and expose 
themselves and others to the danger of severe or let

-

hal injuries. 

-  Have all works only performed by qualified per-

sons.

-  Keep insufficiently qualified persons out of the wor

-

king area.

Protective goggles

The goggles protect the eyes from flying parts and 
liquid splashes.

Protective gloves

The protective gloves serve to protect the hands 
against sharp components as well as against fric-
tion, abrasions or deep injuries. 

Safety boots

Safety boots protect the feet from being crushed, fal

-

ling parts and slipping over on slippery ground. 

Protective clothes

Protective clothes are made of a tightly fitted fabric 
without the protruding parts of low tear strength.

Summary of Contents for 7521100

Page 1: ...W ATER P UMP Garden Pump GP 1105 S Operating Instructions GP 1105 C GP 1105 S GP 1105 P GP 1306 S GP 1105 P GP 1306 S GP 1105 C...

Page 2: ...rating company 4 2 3 Requirements to staff 5 2 4 Personal protective equipment 5 2 5 General safety regulations 5 2 6 Safety labels on the water pump 7 3 Intended use 7 3 1 Improper use 7 3 2 Residual...

Page 3: ...dge gained from using the application which then could be shared and be valuable to develop our products even further 1 3 Limitation of liability All information and notes in these operating instructi...

Page 4: ...correspond to the current status of the regulations and must ad apt these if necessary The operating company must unambiguously regu late and determine the responsibilities for installa tion operation...

Page 5: ...o protect per sons against impairments of safety and health while wor king The staff member has to wear personal protec tive equipment while performing different tasks on and with the machine which ar...

Page 6: ...ot used for a long time drain the piping system to prevent ice from forming in the pump chamber ATTENTION Store the device taking into account its weight viz on a firm level surface and only in a clos...

Page 7: ...ne is put to its intended use there are still residual risks which are listed below Risk of injury of upper and lower limbs while equip ment is operating Heat build up on components can cause burns an...

Page 8: ...8 m 8 m Engine speed 2850 min 2850 min Engine power 1100 W 1100 W Cooling Air cooling Air cooling Sound pressure level 82 dB 84 dB Running time at 75 load 4000 Std 4000 Std Length of cable 1 5 m 1 5...

Page 9: ...ms may be parked on it Step 1 Turn off the water pump and drain completely Wipe all accessible surfaces and let the water pump dry Step 2 Disconnect the suction and discharge lines from the pump and s...

Page 10: ...ording to the current water level in the water tank Display functions GP 1105 S Fig 7 Display functions GP 1105 S The water pump GP 1105 S has a LCD display with two buttons SET and CHECK which makes...

Page 11: ...can cause damage When laying the connecting cables make sure that no weight vibrations or tensions are applied to the pump In addition the connecting cables must not be damaged or have a counterfall t...

Page 12: ...ne person Other persons must keep away from the water pump during operation ATTENTION Make sure that only fresh water is pumped with the water pump Using the water pump for other fluids will damage th...

Page 13: ...that are not resistant to internal pressure may cause the pres sure line to burst during operation This may cause injury due to liquid escaping from the line DANGER Danger to life due to electric shoc...

Page 14: ...d with water If this venting is omitted the pump does not suck in the pumped liquid It is recom mended but not necessary in addition to deaerate the suction line or to fill it with water ATTENTION Dry...

Page 15: ...ce For any trans port the pump must be disconnected from the mains The pump must be completely emptied and stored in a frost proof condition Only a regularly maintained and well maintained device can...

Page 16: ...are available from the manufacturer of the lubricants If necessary request the product specific data sheets 13 Disturbances possible causes and measures ATTENTION If one of the following errors occurs...

Page 17: ...nozzle in take manifold suction hose or filter 1 Remove blockages 2 Clean or change the filter 3 Insert the filter cover correctly 4 Check correct installation position of the filter Pump is not runni...

Page 18: ...an for the water pump GP 1105 C must be ordered The fan wheel has the number 35 in the spare part dra wing Type of device Garden pump GP 1105 C Item number 7521100 Position number 35 The order number...

Page 19: ...re Parts Drawing GP 1105 C In case of the service the following drawing shall help to identify the necessary spare parts If necessary send a copy of the parts drawing with the marked components to you...

Page 20: ...20 GP Series Version 1 03 Spare Parts 14 3 Spare Parts Drawing GP 1105 P Fig 11 Spare Parts Drawing GP 1105 P 14 4 Spare Parts Drawing GP 1105 S Fig 12 Spare Parts Drawing GP 1105 S...

Page 21: ...Spare Parts GP Series Version 1 03 21 14 5 Spare Parts Drawing GP 1306 S Fig 13 Spare Parts Drawing GP 1306 S...

Page 22: ...22 GP Series Version 1 03 Wiring Diagrams 15 Wiring Diagrams GP 1105 S Fig 14 Wiring Diagram GP 1105 S GP 1306 S 1105 P und 1105 C Fig 15 Wiring Diagram GP 1306 S 1105 P and 1105 C...

Page 23: ...DIN EN 60335 1 2012 Household and similar electrical appliances Safety Part 1 General requirements DIN EN 60335 2 41 Household and similar electrical appliances Safety Part 2 41 Particular requirement...

Page 24: ...www cleancraft de...

Reviews: