background image

16

GP - Series | Version 1.03

Disposal, recycling of used device

12 Disposal, recycling of used device

Please take care in your own interest and in the interest 
of the environment that all component parts of the ma-
chine are only disposed of in the intended and permit-ted 
way. 

12.1  Decommissioning

Immediately decommission disused machines in order to 
avoid later misuse and endangering of the environ-ment 
or personal safety.

- Eliminate all environmentally hazardous operating ma

-

terials from the used device.

- If required, disassemble the machine into easy-to-

handle and usable components and parts.

- Dispose of machine components and operating materi

-

als by the disposal channels provided.

12.2 Waste disposal of electric equipment

Please note that electrical devices contain a variety of 
recyclable materials as well as environmentally harmful 
components. 

You contributes to that these components are disposed 
of separately and properly. In case of doubt, please con

-

tact your municipal waste disposal. As necessary, a spe

-

cialized waste disposal company can help be used for 
the treatment. 

12.3 Disposal of lubricants

Please pay attention to an environmentally friendly dis-
posal of the used coolants and lubricants.

Observe the disposal instructions of your municipal dis-
posal companies.Disposal notes for used lubricants are 
available from the manufacturer of the lubricants. If 
necessary, request the product-specific data sheets.

13 Disturbances, possible causes and 

measures

ATTENTION!

If one of the following errors occurs, immediately stop 
working with the water pump.
Before you begin troubleshooting, turn off the water 
pump and unplug the power card. Otherwise it could 
lead to serious injuries.
All repairs or replacement work may only be carried 
out by qualified and trained specialist personnel.

NOTE!

If you can not solve the problems with the your house 
water system yourself, then please contact your ne-
arest CLEANCRAFT dealer. Please write down follo-
wing information from the water pump or the opera-
ting instructions in advance  to help you your problem 
in the best possible way. 

-Model name of the device

-Serial number of the device

-Constructions year

-Exact error description 

Malfunction

Possible cause

Measurement

The motor can not be 
started

1. No power available.
2. Capacitor is defective.
3. The rotating shaft and bearing. 

are jammed.

4. The impeller is jammed.

1. Check with a GS-compliant device whether volt

-

age is present. Check mains plug.

2. Contact customer service.
3. Check the cause and remove the blockage from 

the pump.

4. Turn the rotating shaft of the fan blade connector 

with a screwdriver or disassemble the pump. 
body to remove small parts.

The pump does not reach 
the desired pressure.

1. Cut-out pressure set too high.

1. Contact customer service

Pump does not start.

1. Cut-out pressure set too low.

1. Contact customer service

Summary of Contents for 7521100

Page 1: ...W ATER P UMP Garden Pump GP 1105 S Operating Instructions GP 1105 C GP 1105 S GP 1105 P GP 1306 S GP 1105 P GP 1306 S GP 1105 C...

Page 2: ...rating company 4 2 3 Requirements to staff 5 2 4 Personal protective equipment 5 2 5 General safety regulations 5 2 6 Safety labels on the water pump 7 3 Intended use 7 3 1 Improper use 7 3 2 Residual...

Page 3: ...dge gained from using the application which then could be shared and be valuable to develop our products even further 1 3 Limitation of liability All information and notes in these operating instructi...

Page 4: ...correspond to the current status of the regulations and must ad apt these if necessary The operating company must unambiguously regu late and determine the responsibilities for installa tion operation...

Page 5: ...o protect per sons against impairments of safety and health while wor king The staff member has to wear personal protec tive equipment while performing different tasks on and with the machine which ar...

Page 6: ...ot used for a long time drain the piping system to prevent ice from forming in the pump chamber ATTENTION Store the device taking into account its weight viz on a firm level surface and only in a clos...

Page 7: ...ne is put to its intended use there are still residual risks which are listed below Risk of injury of upper and lower limbs while equip ment is operating Heat build up on components can cause burns an...

Page 8: ...8 m 8 m Engine speed 2850 min 2850 min Engine power 1100 W 1100 W Cooling Air cooling Air cooling Sound pressure level 82 dB 84 dB Running time at 75 load 4000 Std 4000 Std Length of cable 1 5 m 1 5...

Page 9: ...ms may be parked on it Step 1 Turn off the water pump and drain completely Wipe all accessible surfaces and let the water pump dry Step 2 Disconnect the suction and discharge lines from the pump and s...

Page 10: ...ording to the current water level in the water tank Display functions GP 1105 S Fig 7 Display functions GP 1105 S The water pump GP 1105 S has a LCD display with two buttons SET and CHECK which makes...

Page 11: ...can cause damage When laying the connecting cables make sure that no weight vibrations or tensions are applied to the pump In addition the connecting cables must not be damaged or have a counterfall t...

Page 12: ...ne person Other persons must keep away from the water pump during operation ATTENTION Make sure that only fresh water is pumped with the water pump Using the water pump for other fluids will damage th...

Page 13: ...that are not resistant to internal pressure may cause the pres sure line to burst during operation This may cause injury due to liquid escaping from the line DANGER Danger to life due to electric shoc...

Page 14: ...d with water If this venting is omitted the pump does not suck in the pumped liquid It is recom mended but not necessary in addition to deaerate the suction line or to fill it with water ATTENTION Dry...

Page 15: ...ce For any trans port the pump must be disconnected from the mains The pump must be completely emptied and stored in a frost proof condition Only a regularly maintained and well maintained device can...

Page 16: ...are available from the manufacturer of the lubricants If necessary request the product specific data sheets 13 Disturbances possible causes and measures ATTENTION If one of the following errors occurs...

Page 17: ...nozzle in take manifold suction hose or filter 1 Remove blockages 2 Clean or change the filter 3 Insert the filter cover correctly 4 Check correct installation position of the filter Pump is not runni...

Page 18: ...an for the water pump GP 1105 C must be ordered The fan wheel has the number 35 in the spare part dra wing Type of device Garden pump GP 1105 C Item number 7521100 Position number 35 The order number...

Page 19: ...re Parts Drawing GP 1105 C In case of the service the following drawing shall help to identify the necessary spare parts If necessary send a copy of the parts drawing with the marked components to you...

Page 20: ...20 GP Series Version 1 03 Spare Parts 14 3 Spare Parts Drawing GP 1105 P Fig 11 Spare Parts Drawing GP 1105 P 14 4 Spare Parts Drawing GP 1105 S Fig 12 Spare Parts Drawing GP 1105 S...

Page 21: ...Spare Parts GP Series Version 1 03 21 14 5 Spare Parts Drawing GP 1306 S Fig 13 Spare Parts Drawing GP 1306 S...

Page 22: ...22 GP Series Version 1 03 Wiring Diagrams 15 Wiring Diagrams GP 1105 S Fig 14 Wiring Diagram GP 1105 S GP 1306 S 1105 P und 1105 C Fig 15 Wiring Diagram GP 1306 S 1105 P and 1105 C...

Page 23: ...DIN EN 60335 1 2012 Household and similar electrical appliances Safety Part 1 General requirements DIN EN 60335 2 41 Household and similar electrical appliances Safety Part 2 41 Particular requirement...

Page 24: ...www cleancraft de...

Reviews: