7
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
In case of a fixed installation, it is
recommended that you fit a non-
return valve on both sides of the
pump. This allows closure of the line
upstream and/or downstream from
the pump, useful for service and
cleaning operations or for periods in
which the pump is not in use.
To capture small particles in
suspension an inlet filter should be
fitted on the suction pipe to protect
the integrated filter (1).
SUCTION LIFT OR GRAVITY FEED
SUCTION LIFT
It is possible to draw water up from a
sunken pool or well.
• The vertical distance between
the foot valve and the pump
should not exceed 8 metres.
It is essential that all connections and
hoses are completely air tight,
otherwise the system will not work.
GRAVITY FEED
The pump can draw water from an
above ground tank.
A foot valve/filter should be fitted to
the end of the suction hose, (as
illustrated), to help retain water in the
suction system.
Summary of Contents for EBP1100