6) MAX PUMP ON:
This is the maximum period of operation. The function can
be enabled or disabled. The factory setting is disabled.
When enabled, if the pump operates for more than 30 minutes it will be
stopped. No error indication is displayed.
This function is used to protect the installation if a valve is accidentally left
open, or in the event of breakage of a pipe, or in applications for irrigation.
To enable the
MAX PUMP ON
function, press
“MODE”
until the LED
corresponding to the
MAX PUMP ON
function comes on, then press
SET
until
the
“ON”
LED comes on. To disable
MAX PUMP ON
, press SET until the LED
illuminates to indicate OFF.
SET SELECTION BUTTON (C)
SELECTABLE MODES
1. Reset Alarms;
2. Enable/disable in MODE (MAX_PUMP_ON, ANTI-LEAKAGE)
3. Increases parameters in MODE (CUT_IN; CUT_OUT);
4. Motor ON/OFF in MANUAL MODE;
5. Pump active/pump in standby in AUTO MODE
Press
“SET”
to modify the parameters. If the LED is shows CUT IN or CUT OUT, the
value will be shown on the Pressure Indication LED bar. When pressing
“SET”
the value will increase. After setting the required value, exit the modification
by pressing
“MODE”
and restore the LED to MODE-AUTO and SET “ON”
enabled.
Press
SET
also to enable/disable the ANTI-LEAKAGE and MAX PUMP ON
functions. After selecting the function using the “MODE” button, enable it by
selecting SET-ON, to disable it select SET-OFF.
In
“MANUAL”
mode, the
SET
button is used to switch the pump on or off, with
the LED showing “On” or “OFF”.
In automatic mode AUTO-MODE is used to turn it “ON” or in standby turn it
“OFF”.
PUMP ON
: This indication shows that PUMP ON coincides with the motor
running.