TROUBLESHOOTING

Problem

Cause

Solution

Pump does not run.

Thermal protection has 
been activated.

If the motor has over-
heated, wait for it to cool 
down before trying 
again.

Faulty power connection Insert plug securely.

No mains supply.

Check fused power   
supply and replace fuse 
if necessary (check fuse 
rating). Check circuit 
breaker.

Impeller seized/blocked

Disconnect pump from 
power supply.            
Investigate cause and 
clear blockage

Pump fails to prime

Air leaks through suction 
hose joints (damaged 
hose or damaged 
clamp.)

Repair connections/
replace hose as          
necessary.

Blocked inlet hose

Check pipeline for block-
age. Check any inlet 
valve fitted is fully open.

Pump runs but gives poor 
output

Congested material 
inside pump

Clean out & backflush 
pump.

Suction or delivery line 
obstructed.

Remove obstruction and 
ensure there are no kinks 
in delivery line.

Inlet pipe leakage.

Check inlet pipe and 
connector for leaks. 
Tighten as required.

Air leaks through       
damaged seal.

Renew seal.

Impeller damaged and 
making poor seal.

Return to your CLARKE 
dealer for repair.

Impeller / mechanical 
seal is badly worn.

Return to your CLARKE 
dealer for repair.

Summary of Contents for EBP1100

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0819 ISS 1 ELECTRIC BOOSTER SURFACE PUMP MODEL NO EBP1100 PART NO 7239200...

Page 2: ...ure for a period of 12 months from the date of purchase Please keep your receipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or ta...

Page 3: ...ater Classification Clean Maximum Delivery 62 5 l min Maximum Head 45 m Maximum Suction Lift 8 m Operating Temperature 0 35o C Ingress Protection Rating IPx4 Supply 230V 50Hz Rated Power 1100 W Input...

Page 4: ...properly installed to prevent it from moving during operation and that the immediate area surrounding the pump is kept clear 6 ALWAYS maintain the pump with care and keep it clean for best safest per...

Page 5: ...7 Vibration damping rubber feet 8 Digital control panel 9 Flow meter 10 Handle Because of the number of possible installations no accessories are supplied with your pump but a selection is available f...

Page 6: ...distance away If in doubt please contact your electrician and refer to national regulations Avoid locating the pump where it could become drenched with water as it is not designed to be totally waterp...

Page 7: ...rticles in suspension an inlet filter should be fitted on the suction pipe to protect the integrated filter 1 SUCTION LIFT OR GRAVITY FEED SUCTION LIFT It is possible to draw water up from a sunken po...

Page 8: ...er cable must agree with the markings on the plug Connect the BLUE wire to the terminal marked N Connect the BROWN wire to the terminal marked L Connect the YELLOW AND GREEN wire to the terminal marke...

Page 9: ...electronic system incorporates the following controls A PRESSURE INDICATOR LEDS 10 LEDs are used for indicating pressure from 0 to 6 bar B MODE SELECTION BUTTON Selectable modes include 1 AUTO_MODE 2...

Page 10: ...The factory setting is disabled When enabled if the pump is started up more than 6 times in 2 minutes it will be stopped and the error will be indicated by means of the red LED flashing slowly on ALAR...

Page 11: ...TTON C SELECTABLE MODES 1 Reset Alarms 2 Enable disable in MODE MAX_PUMP_ON ANTI LEAKAGE 3 Increases parameters in MODE CUT_IN CUT_OUT 4 Motor ON OFF in MANUAL MODE 5 Pump active pump in standby in AU...

Page 12: ...LED will light up When the pump starts working it will enter PRIMING mode NOTE Make sure the instructions for installation have been followed and that the pump is filled completely with water 2 PRIMI...

Page 13: ...alarm is reset see 3 a new attempt will be made after 40 sec Eliminate the cause of dry running and reset the alarm see 3 8 ANTI LEAKAGE This function may be enabled or disabled When enabled should t...

Page 14: ...by the red LED in SET ALARM Eliminate the cause and reset the alarm see 3 OPERATION WITH CUT OUT DISABLED FACTORY SETTING CUT OUT disabled means the following response occurs The pump is activated if...

Page 15: ...process and it is suggested that a non return valve be fitted to the end of the suction pipe START UP 1 Plug the power cable into a 230 V power socket and switch on 2 The pump motor will start and wat...

Page 16: ...r corrosive liquids other than pool purification chemicals in their correct mix ratio 4 If the pump is being used to drain a pool or pond ensure there is adequate drainage and there is no risk of dama...

Page 17: ...e etc The pump should not be taken apart by the user if overhaul is required but should be taken to your nearest CLARKE dealer for repair CLEANING THE SUCTION FILTER 1 Switch off the electric power su...

Page 18: ...clear blockage Pump fails to prime Air leaks through suction hose joints damaged hose or damaged clamp Repair connections replace hose as necessary Blocked inlet hose Check pipeline for block age Chec...

Page 19: ...n loss of flow Blockage of inlet pipe Check pipeline for blockage Undue vibration or noise Excessive flow of water Decrease flow of water by adjusting inlet outlet valves in system Resistance in inlet...

Page 20: ...20 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com COMPONENT PARTS GENERAL...

Page 21: ...ase assembly 9 O ring 28 Sensor assembly 10 O ring 29 Fork 11 Bearing 30 O ring 12 Shaft seal 31 Power box cable grommet 13 Impeller 32 Terminal box cover 14 Pump body assembly 33 Screw 15 Washer 34 F...

Page 22: ...larkeinternational com COMPONENT PARTS PUMP ONLY 1 Pump body 10 O ring 2 Inlet connector 11 O ring 3 Inner valve body 12 O ring 4 Non return valve 13 Venturi assembly 5 Filter with base 14 Filter cap...

Page 23: ...23 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Page 24: ......

Reviews: