10
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
USING THE MODE SELECTION BUTTON (B)
1. To unlock the choice of functions press “MODE” button for 5 seconds.
2. Press
“MODE”
to scroll through the various operating modes or parameters
to be modified or to enable certain functions.
• While scrolling through the modes, the LED of the function selected
will flash.
• On returning to AUTO_MODE the active functions will be highlighted
by the relative LED lighting up.
THE OPTIONS ARE AS FOLLOWS:
1) AUTO MODE:
the pump will run in automatic mode see page 12.
2) MANUAL MODE:
the pump works in manual mode see page 12, and the
user can decide when to switch it on or off by using the
“SET”
button. SET-ON
switched On /
SET-OFF
switched Off.
3) ANTI-LEAKAGE:
This function is for protection against leakage and can be
enabled or disabled. The factory setting is disabled.
When enabled, if the pump is started up more than 6 times in 2 minutes, it will
be stopped and the error will be indicated by means of the red LED flashing
slowly on
“ALARM”
.
To enable ANTI-LEAKAGE, press “MODE” until the LED flashes, then press SET
until the “ON” LED is lit up. To disable ANTI-LEAKAGE press SET until the LED
indicates OFF.
Once the leak is repaired, reset the alarm, if still present, see alarm reset on
page 12.
4) CUT-IN:
This is the pressure setting (always enabled) at which the pump is
activated. It can be set between 1.5 and 3.0 bar, (factory setting 1.8 bar). The
pump is activated even if the flow is less than a minimum value of 1.5 l/min,
(factory-setting).
5) CUT-OUT
: This is the pressure setting (disabled) above which the pump stops.
This is a factory setting for “CUT-IN” + 1 LED, but can be increased to 6 bar.
To enable CUT OUT press “MODE” until the LED corresponding to CUT-OUT
flashes then press SET to select the required value. Exit the setting by pressing
“MODE”. To disable the function, press “SET” until the LED indicates OFF.
Summary of Contents for EBP1100