GENERAL SAFETY PRECAUTIONS 

Before using this equipment it is in your own interest to read and pay attention 
to the following safety rules.

1. ALWAYS keep the working area clean and well lit. Floors should always be 

kept clear. Cluttered or dark areas invite accidents.

2. NEVER over-reach. Keep your proper footing and balance at all times 

when installing or maintaining the pump.

3. NEVER

 

direct any water discharge towards electrical wiring or equipment.

4. ALWAYS

 

thoroughly familiarise yourself with this pump & its operation, and 

follow all instructions in this manual.

 

Never allow persons unfamiliar with 

these instructions to instal or operate the pump.

5. ALWAYS

 

ensure that the pump is properly installed to prevent it from moving 

during operation, and that the immediate area surrounding the pump is 
kept clear.

6. ALWAYS maintain the pump with care and keep it clean for best / safest 

performance.

7. NEVER modify this pump in any way. Use it ONLY for the purpose for which it 

is designed.

8. NEVER use for pumping flammable liquids or corrosive chemicals. This 

pump is designed to pump clean water only.

9. ALWAYS have the pump serviced by your local CLARKE dealer, using only 

identical replacement parts. This will ensure the safety of the pump is 
maintained. The use of non standard parts could be hazardous.

10. NEVER use this product if any part is damaged. Have it inspected and 

repaired by your local Clarke dealer. Always turn the pump off before 
carrying out any maintenance.

11. NEVER allow the pump to run dry.

WARNING: ALWAYS CONNECT THE PUMP TO AN EARTHED POWER SUPPLY 
VIA AN RCD.

CAUTION: THIS PUMP IS NOT A SUBMERSIBLE PUMP. ON NO ACCOUNT 
SHOULD IT EVER BE IMMERSED IN WATER.

Summary of Contents for EBP1100

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0819 ISS 1 ELECTRIC BOOSTER SURFACE PUMP MODEL NO EBP1100 PART NO 7239200...

Page 2: ...ure for a period of 12 months from the date of purchase Please keep your receipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or ta...

Page 3: ...ater Classification Clean Maximum Delivery 62 5 l min Maximum Head 45 m Maximum Suction Lift 8 m Operating Temperature 0 35o C Ingress Protection Rating IPx4 Supply 230V 50Hz Rated Power 1100 W Input...

Page 4: ...properly installed to prevent it from moving during operation and that the immediate area surrounding the pump is kept clear 6 ALWAYS maintain the pump with care and keep it clean for best safest per...

Page 5: ...7 Vibration damping rubber feet 8 Digital control panel 9 Flow meter 10 Handle Because of the number of possible installations no accessories are supplied with your pump but a selection is available f...

Page 6: ...distance away If in doubt please contact your electrician and refer to national regulations Avoid locating the pump where it could become drenched with water as it is not designed to be totally waterp...

Page 7: ...rticles in suspension an inlet filter should be fitted on the suction pipe to protect the integrated filter 1 SUCTION LIFT OR GRAVITY FEED SUCTION LIFT It is possible to draw water up from a sunken po...

Page 8: ...er cable must agree with the markings on the plug Connect the BLUE wire to the terminal marked N Connect the BROWN wire to the terminal marked L Connect the YELLOW AND GREEN wire to the terminal marke...

Page 9: ...electronic system incorporates the following controls A PRESSURE INDICATOR LEDS 10 LEDs are used for indicating pressure from 0 to 6 bar B MODE SELECTION BUTTON Selectable modes include 1 AUTO_MODE 2...

Page 10: ...The factory setting is disabled When enabled if the pump is started up more than 6 times in 2 minutes it will be stopped and the error will be indicated by means of the red LED flashing slowly on ALAR...

Page 11: ...TTON C SELECTABLE MODES 1 Reset Alarms 2 Enable disable in MODE MAX_PUMP_ON ANTI LEAKAGE 3 Increases parameters in MODE CUT_IN CUT_OUT 4 Motor ON OFF in MANUAL MODE 5 Pump active pump in standby in AU...

Page 12: ...LED will light up When the pump starts working it will enter PRIMING mode NOTE Make sure the instructions for installation have been followed and that the pump is filled completely with water 2 PRIMI...

Page 13: ...alarm is reset see 3 a new attempt will be made after 40 sec Eliminate the cause of dry running and reset the alarm see 3 8 ANTI LEAKAGE This function may be enabled or disabled When enabled should t...

Page 14: ...by the red LED in SET ALARM Eliminate the cause and reset the alarm see 3 OPERATION WITH CUT OUT DISABLED FACTORY SETTING CUT OUT disabled means the following response occurs The pump is activated if...

Page 15: ...process and it is suggested that a non return valve be fitted to the end of the suction pipe START UP 1 Plug the power cable into a 230 V power socket and switch on 2 The pump motor will start and wat...

Page 16: ...r corrosive liquids other than pool purification chemicals in their correct mix ratio 4 If the pump is being used to drain a pool or pond ensure there is adequate drainage and there is no risk of dama...

Page 17: ...e etc The pump should not be taken apart by the user if overhaul is required but should be taken to your nearest CLARKE dealer for repair CLEANING THE SUCTION FILTER 1 Switch off the electric power su...

Page 18: ...clear blockage Pump fails to prime Air leaks through suction hose joints damaged hose or damaged clamp Repair connections replace hose as necessary Blocked inlet hose Check pipeline for block age Chec...

Page 19: ...n loss of flow Blockage of inlet pipe Check pipeline for blockage Undue vibration or noise Excessive flow of water Decrease flow of water by adjusting inlet outlet valves in system Resistance in inlet...

Page 20: ...20 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com COMPONENT PARTS GENERAL...

Page 21: ...ase assembly 9 O ring 28 Sensor assembly 10 O ring 29 Fork 11 Bearing 30 O ring 12 Shaft seal 31 Power box cable grommet 13 Impeller 32 Terminal box cover 14 Pump body assembly 33 Screw 15 Washer 34 F...

Page 22: ...larkeinternational com COMPONENT PARTS PUMP ONLY 1 Pump body 10 O ring 2 Inlet connector 11 O ring 3 Inner valve body 12 O ring 4 Non return valve 13 Venturi assembly 5 Filter with base 14 Filter cap...

Page 23: ...23 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Page 24: ......

Reviews: