17
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
MAINTENANCE & CLEANING
The only maintenance required is a regular inspection to ensure that debris is
not blocking the passage of water through the pump.
If you suspect the pump is blocked by silt, leaf debris etc, disconnect it from
the power supply and back-flush to clear any blockage using a garden hose.
• You will need to disconnect the outlet hose to do this.
Always keep the pump in a clean condition, checking regularly for loose bolts
or a damaged power cable etc.
The pump should not be taken apart by the user if overhaul is required, but
should be taken to your nearest CLARKE dealer for repair.
CLEANING THE SUCTION FILTER
1. Switch off the electric power
supply to the pump.
2. Drain the pump by removing the
drainage plug after having first
closed any gate valves upstream.
3. Unscrew the cover of the filter
chamber using the wrench
provided.
4. Remove the filter unit from the top.
5. Rinse the unit under running water
& clean the filter with a soft brush.
6. Re-fit the parts in reverse order to
disassembly.
CLEANING THE NON RETURN VALVE
1. Switch off the power supply to the
pump.
2. Remove the cap of the NRV with
the wrench provided.
3. Remove the NRV and clean it
thoroughly.
4. Re-fit the parts in reverse order to
disassembly.
Summary of Contents for EBP1100