11
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
7. Ensure there is sufficient clearance to allow the complete table assembly
to move around the column. If necessary, reposition the collar to achieve
good movement.
8. Check that the table moves smoothly from top to bottom of the rack by
turning the crank handle.
HEAD TO COLUMN
NOTE:
It
may be necessary to unscrew the
set screws (shown in fig 5) to
ensure they do not protrude internally and foul the column, as this
would prevent the head from sliding fully into position.
1. With the help of an assistant, lift up
the head assembly and locate it
on the column, ensuring it slides
fully home.
2. Align the head assembly with the
base and tighten the head
locking set screws shown in Fig 6
using the hex key supplied.
3. Take the feed handle assembly
and screw it firmly onto the hub of
the feed shaft as shown in Fig 7.
Add the hub cover with its
retaining screw.
INSTALLING THE CHUCK
1. Open the jaws of the chuck as far
as possible using the chuck key
supplied or by manually turning
the chuck barrel clockwise. E
nsure
the tapered hole in the chuck is
clean and fit the chuck onto the
tapered end of the drive spindle
with a firm pressure
.