36
2-3 RUN TIME 12/24/60 MINUTES:
This feature controls how long the engine will run before
it “times out” and shuts down. Programmed to the default setting the engine will run for 12
minutes. If the 24-minute run time is desired, change this feature to the on-board LED off setting.
2-4 FLASHING PARKING LIGHT OUTPUT:
In the default setting, the unit will flash the vehicle’s park-
ing lights while remote started. The constant setting will turn the parking lights on solidly for the entire
run duration.
2-5 CRANKING TIME 0.6/0.8/1.0/1.2/1.4/1.6/1.8/2.0/4.0:
If feature 2-2 is programmed to the
voltage sense setting, the crank time must be set to the appropriate duration. The default setting is
0.6 seconds. If a different crank time is desired, select feature 2.5 and (while pressing the Override
switch) advance to the next time by pressing the channel 2 button. The unit will flash the LED to indi-
cate which time is selected. Once the 4.0 second setting is reached the next press of channel 2 will
reset the system to the shortest setting.
2-6 VOLTAGE CHECK LEVEL HIGH/LOW:
This feature only functions when Feature 2-2 is pro-
grammed to voltage sense. Some vehicles have many accessories, which are turned on when remote
started. In these vehicles, the variation of voltage between the engine off and the vehicle running is
very slight and the remote start unit may “think” the vehicle has not started. This can cause the remote
start to shut down after the vehicle has been started. If this is the case, program this feature to the
LOW position.
2-7 SHORT RUN (TURBO TIMER):
When the
and
buttons on the remote are pressed
simultaneously, the vehicle will continue to run for the programmed short-run time. The factory
default is 1 minute.
2-8 ACTIVATION PULSE COUNT:
This feature allows the number of pulses to activate the remote start
feature to be changed from 1, 2, or 3 pulses. The pulse count programmed to start the vehicle will
also be the same required to shut down the remote start.
2-9 2nd IGNITION/ACCESSORY OUTPUT:
This will allow the PINK/WHITE to be used as a 2nd igni-
tion or an accessory.
2-10 ACCESSORY STATE DURING WAIT-TO-START:
This will allow the programming of the accesso-
ry wire during the wait-to-start period of a diesel motor. When ON the accessory comes on when
the wait-to-start output is activated and stays on, dropping out during crank and returning once the
car has started. When OFF the accessory will activate as a normal accessory.
2-11 2nd STATUS OUTPUT:
This status will activate 10 seconds after the car has started. It is intend-
ed to operate the defogger circuit. The output can be programmed to a latched or a pulsed output.
When programmed to the latched output the status will only stay active for 10 minutes.
Summary of Contents for Ungo Pro Security RK1
Page 43: ...43 wiring quick reference guide Lo Hi ...
Page 44: ...44 relay satellite wiring quick reference guide ...
Page 45: ...45 ...