background image

DSX SERVOTRONIC MPS

®

16

7. Electrical connection

Check that the power supply is switched 
off prior to electrical connection!

1.  Open the prepared breaking point (S) in 

the upper part of the appliance by pressing 
with a blunt implement (e.g. srewdriver).

2.  Slit the grommet to match the cable size. 

The opening in the grommet should be 
slightly smaller than the cross­section 
of the cable in order to ensure optimum 
protection against water. Fit the grommet 
into the opening. The protection grommet 
must be used!

3.  Dismantle the cable roughly 6 cm above 

the point where it emerges from the wall. 
Hold the prepared appliance so that you 
can route the cable into the grommet with 
the other hand.

4.  Place the appliance on the heater bracket 

so that the threaded rod of the wall 
bracket fits in the provided hole of the 
appliance.

5.  Open the control panel rightwards.
6.  Unscrew the fastening screw of the con­

necting terminal. Displace the connecting 
terminal to the upper foot. Affix the con­
necting terminal again.

7.  Strip the cables and plug them in the con­

necting terminals according to the wiring 
diagram. The appliance must be earthed.

8.  Reinsert the control panel and lock it on 

the heating element.

9.  Place the hood on the appliance and screw 

in the fastening screw. After that you can 
reinsert the faceplate.

Electrical connection from above

7. Электроподключение

Перед выполнением 
электроподключения убедитесь в 
отсутствии подачи напряжения на 
прибор!

1.  Откройте подготовленное место 

(S), расположенное в верхней части 
прибора, надавив тупым инструментом 
(например, отверткой). 

2.  Сделайте отверстие в изоляционной 

втулке, соответствующее диаметру 
кабеля. Величина отверстия должна 
быть чуть меньше диаметра кабеля. 
Это обеспечит оптимальную защиту 
от воды. Вставьте проходную 
изоляционную втулку в отверстие. 
Использование изоляционной втулки 
обязательно!

3.  Снимите оболочку провода 

приблизительно в 6 см над местом 
его выхода из стены. Одной рукой 
придерживая прибор, другой рукой 
заведите кабель в изоляционную 
втулку. 

4.  Установите прибор на стенной 

кронштейн так, чтобы резьбовой 
стержень кронштейна зашел в 
отверстие прибора. 

5.  Откройте панель управления 

движением вправо. 

6.  Открутите крепежный винт клеммной 

колодки. Перенесите клеммную колодку 
в верхнюю часть прибора. Закрепите 
клеммную колодку на держателе.

7.  Зачистите концы кобелей и вставьте их 

в клеммы в соответствии с монтажной 
схемой. Прибор должен быть заземлен.

8.  Установите на место панель управления 

и зафиксируйте ее на нагревательном 
элементе.

9.  Установите лицевую панель и закрутите 

крепежный винт. Затем установите на 
место заглушку. 

Электроподключение сверху

Summary of Contents for DSX SERVOTRONIC MPS

Page 1: ...Installing instructions for the professional 11 15 DSX E convenience instant water heater DSX...

Page 2: ...ction 13 Wiring diagram 13 Structural prerequisites 13 Load shedding relay 13 Electrical connection from below 15 Electrical connection from above 16 8 Initial operation 17 Selection of power rating 1...

Page 3: ...r connection Fine filter Water splash protection sleeve Grommet Screw in nipples inch DSX DSX hood Non return valve Flow sensor Thermal sensor set Thermal sensor set Outlet pipe Bottom part Wall brack...

Page 4: ...43 C are perceived as hot especially by children and may cause a feeling of burning Please note that the fittings and taps may be very hot when the appliance has been in use for some time The applian...

Page 5: ...CLAGE 2 Safety instructions The remote control and the wall bracket should not get close to items with magnetic strips like credit cards etc The built in magnets can damage the card s magnetic strip...

Page 6: ...d flow rate to switch on 0 2 2 5 1 3 9 0 Pressure loss 20 C 60 C Temperature range G Water connection 4 2 Weight when filled with water VDE I VDE class of protection PA IX 6822 I Noise level test cert...

Page 7: ...ls must be used 5 Installation Installation site Appliance must only be installed in frost free rooms Never expose appliance to frost The Appliance must be wall mounted and has to be installed with wa...

Page 8: ...mainte nance work Plastic pipes may only be used if they con form to DIN 16893 Series 2 The hot water pipes must be thermally insulated The specific resistance of the water must be at least 1100 cm at...

Page 9: ...he wall connections The seals must be fully screwed into the thread After tightening the double nipples must protrude by at least 12mm 2 Hold the included mounting template on the wall and align it so...

Page 10: ...s Electrical connection from above 2 Place the appliance on the heater bracket so that the threaded rod of the wall bracket fits in the provided hole of the appliance If necessary slight corrections a...

Page 11: ...s 4mm and screws as shown in the figure B When using the adhesive tape it is not possible to further adjust the position because of the strong adherence of the glue Therefore pay attention to a horizo...

Page 12: ...inch union nut of the appliance and delivery pipe together with the 3 8 inch seals For direct connection it is advisable to mount the appliance at a distance as illustrated alongside using the spacer...

Page 13: ...s CLAGE no 82250 can be connected to phase conductor L2 LCD Description 0 Normal operation manufacturer s setting 1 Operation with normal load shedding relay 2 Operation with sensitive load shedding r...

Page 14: ...You can now select between mode 0 1 and 2 with the aid of arrow key and A new pressing on the setup key will store the new parameter value You will get back to the normal display by pressing the info...

Page 15: ...from coming into contact with the electri cal leads It must not become damaged The protection sleeve must be used 2 Open the control panel rightwards 3 Strip the cables and plug them in the con nectin...

Page 16: ...e wall Hold the prepared appliance so that you can route the cable into the grommet with the other hand 4 Place the appliance on the heater bracket so that the threaded rod of the wall bracket fits in...

Page 17: ...al installation must comply with the statutory regulations of the respective country and those of the local electricity sup ply company Germany DIN VDE 0100 1 Switch on the power supply to the appli a...

Page 18: ...o the water heater and check whether the power supply is turned on Explain the user how the instan ta neous water heater works and hand over the operating instructions for the user 8 Initial operation...

Page 19: ...maintain when activating and deactivating the supply voltage Lock level The operating mode of the appliance can be restricted Activation of the lock level 1 Select required level of Lock level via the...

Page 20: ...ection piece position closed 4 Unscrew the screw plug b from the cold water connection piece and take out the strainer c 5 The strainer can now be cleaned or re placed 6 After fitting of the clean str...

Page 21: ...se the screw behind this cover and detach the hood 4 Unscrew mains water inlet from connection piece and take out the strainer 5 The strainer can now be cleaned or replaced 6 After refitting the clean...

Page 22: ...electronic scrap Disposing it correctly will support environmental protection and will prevent any potential negative effects on human beings and the environment that could arise from inappropriate ha...

Page 23: ......

Page 24: ...on 3 Scalding protec off 1 Display confirms deactivation 2 3 Setup key Info key Programme keys Arrow key up Arrow key down Select preset temp A1 A2 B1 B2 C1 C2 D1 D2 Press 3 Setup menu 2 8 4 7 5 3 6 9...

Reviews: