background image

DSX SERVOTRONIC MPS

®

4

2. Safety instructions 

Please read these instructions carefully before installing or using 
the appliance! Keep the instructions handy with the appliance for 
future use!

Instruction manuals are intended for the specialist who is responsible 
for the installation of the appliance. Operation manuals are for the end 
user. The provided manuals correspond to the technical specifications 
of the appliance.
The latest version of the instructions can be found online at www.clage.
com.

•  Do not use the appliance until it has been correctly 

installed and unless it is in perfect working order. 

•  Do not remove the front cover under any circumstances 

before switching off the mains electrical supply to the 
unit. 

•  Never make technical modifications, either to the appli­

ance itself or the electrical leads and water pipes. 

•  The appliance must be earthed at all times. 
•  Pay attention to the fact that water temperatures in 

excess of approx. 43 °C are perceived as hot, especially 
by children, and may cause a feeling of burning. Please 
note that the fittings and taps may be very hot when 
the appliance has been in use for some time. 

•  The appliance is only suitable for domestic use and 

similar applications inside closed rooms, and must only 
be used to heat incoming water from the mains supply. 

•  The appliance must never be exposed to frost. 
•  The values stated on the rating plate must be observed.
•  In case of malfunction, disconnect the fuses imme­

diately. In case of leaks, cut off the mains water sup­
ply instantly. Repairs must only be carried out by the 
customer service department or an authorised profes­
sional. 

•  This appliance can be used by children aged 8 years 

and above and persons with reduced physical, sen­
sory or mental capabilities or lack of experience and 
knowledge if they have been given supervision or ins­
truction concerning use of the appliance in a safe way 
and understand the hazards involved. Children shall 
not play with the appliance. Cleaning and user main­
tenance shall not be performed by children without 
supervision.

2. Инструкции по технике безопасности 

Перед монтажом и первым включением прибора внимательно 
прочтите данные инструкции. Храните инструкции так, чтобы 
всегда иметь их под рукой.

Инструкции по монтажу предназначены для специалиста, 
выполняющего монтаж прибора. Инструкции по эксплуатации 
предназначены для конечного пользователя. 
Инструкции в последней редакции можно найти на сайте  
www.clage­russia.ru или www.clage.com.

•  Эксплуатация прибора запрещена, если он не 

смонтирован надлежащим образом или не 
находится в исправном рабочем состоянии. 

•  Перед снятием лицевой панели прибора отключите 

его от электросети. 

•  Запрещается вносить технические изменения как 

в сам прибор, так и в элементы электропитания и 
водоснабжения. 

•  Прибор должен быть постоянно заземлен. 
•  Обратите внимание: вода, температура которой 

превышает 43 °C, воспринимается как горячая 
(особенно детьми) и может вызвать болевые 
ощущения. Осторожно: через некоторое время 
после начала работы прибора арматура и краны 
могут сильно нагреться. 

•  Прибор является бытовым и должен использоваться 

исключительно для нагрева водопроводной воды. 

•  Эксплуатация прибора при минусовых 

температурах в помещении запрещена. 

•  Необходимо соблюдать параметры, указанные на 

табличке с паспортными данными прибора.

•  В случае возникновения проблем в работе прибора 

незамедлительно отключите его от электросети. 
В случае протечки незамедлительно перекройте 
подачу воды. Ремонтные работы должны 
осуществляться исключительно специалистом 
сервисной службы. 

•  Детям старше семи лет и лицам с ограниченными 

физическими, сенсорными или умственными 
способностями или недостаточным опытом и 
знаниями пользоваться прибором можно только 
под присмотром или после инструктажа по 
безопасной эксплуатации прибора, когда нет 
сомнений в том, что они осознают опасности, 
связанные с работой прибора. Дети не должны 
играть с прибором. Детям чистить и ухаживать за 
прибором можно только под присмотром взрослых.

Summary of Contents for DSX SERVOTRONIC MPS

Page 1: ...Installing instructions for the professional 11 15 DSX E convenience instant water heater DSX...

Page 2: ...ction 13 Wiring diagram 13 Structural prerequisites 13 Load shedding relay 13 Electrical connection from below 15 Electrical connection from above 16 8 Initial operation 17 Selection of power rating 1...

Page 3: ...r connection Fine filter Water splash protection sleeve Grommet Screw in nipples inch DSX DSX hood Non return valve Flow sensor Thermal sensor set Thermal sensor set Outlet pipe Bottom part Wall brack...

Page 4: ...43 C are perceived as hot especially by children and may cause a feeling of burning Please note that the fittings and taps may be very hot when the appliance has been in use for some time The applian...

Page 5: ...CLAGE 2 Safety instructions The remote control and the wall bracket should not get close to items with magnetic strips like credit cards etc The built in magnets can damage the card s magnetic strip...

Page 6: ...d flow rate to switch on 0 2 2 5 1 3 9 0 Pressure loss 20 C 60 C Temperature range G Water connection 4 2 Weight when filled with water VDE I VDE class of protection PA IX 6822 I Noise level test cert...

Page 7: ...ls must be used 5 Installation Installation site Appliance must only be installed in frost free rooms Never expose appliance to frost The Appliance must be wall mounted and has to be installed with wa...

Page 8: ...mainte nance work Plastic pipes may only be used if they con form to DIN 16893 Series 2 The hot water pipes must be thermally insulated The specific resistance of the water must be at least 1100 cm at...

Page 9: ...he wall connections The seals must be fully screwed into the thread After tightening the double nipples must protrude by at least 12mm 2 Hold the included mounting template on the wall and align it so...

Page 10: ...s Electrical connection from above 2 Place the appliance on the heater bracket so that the threaded rod of the wall bracket fits in the provided hole of the appliance If necessary slight corrections a...

Page 11: ...s 4mm and screws as shown in the figure B When using the adhesive tape it is not possible to further adjust the position because of the strong adherence of the glue Therefore pay attention to a horizo...

Page 12: ...inch union nut of the appliance and delivery pipe together with the 3 8 inch seals For direct connection it is advisable to mount the appliance at a distance as illustrated alongside using the spacer...

Page 13: ...s CLAGE no 82250 can be connected to phase conductor L2 LCD Description 0 Normal operation manufacturer s setting 1 Operation with normal load shedding relay 2 Operation with sensitive load shedding r...

Page 14: ...You can now select between mode 0 1 and 2 with the aid of arrow key and A new pressing on the setup key will store the new parameter value You will get back to the normal display by pressing the info...

Page 15: ...from coming into contact with the electri cal leads It must not become damaged The protection sleeve must be used 2 Open the control panel rightwards 3 Strip the cables and plug them in the con nectin...

Page 16: ...e wall Hold the prepared appliance so that you can route the cable into the grommet with the other hand 4 Place the appliance on the heater bracket so that the threaded rod of the wall bracket fits in...

Page 17: ...al installation must comply with the statutory regulations of the respective country and those of the local electricity sup ply company Germany DIN VDE 0100 1 Switch on the power supply to the appli a...

Page 18: ...o the water heater and check whether the power supply is turned on Explain the user how the instan ta neous water heater works and hand over the operating instructions for the user 8 Initial operation...

Page 19: ...maintain when activating and deactivating the supply voltage Lock level The operating mode of the appliance can be restricted Activation of the lock level 1 Select required level of Lock level via the...

Page 20: ...ection piece position closed 4 Unscrew the screw plug b from the cold water connection piece and take out the strainer c 5 The strainer can now be cleaned or re placed 6 After fitting of the clean str...

Page 21: ...se the screw behind this cover and detach the hood 4 Unscrew mains water inlet from connection piece and take out the strainer 5 The strainer can now be cleaned or replaced 6 After refitting the clean...

Page 22: ...electronic scrap Disposing it correctly will support environmental protection and will prevent any potential negative effects on human beings and the environment that could arise from inappropriate ha...

Page 23: ......

Page 24: ...on 3 Scalding protec off 1 Display confirms deactivation 2 3 Setup key Info key Programme keys Arrow key up Arrow key down Select preset temp A1 A2 B1 B2 C1 C2 D1 D2 Press 3 Setup menu 2 8 4 7 5 3 6 9...

Reviews: