Page 4
WS1TC & WS1.25 TC Manual
Introduction
This manual is about a control valve to be used on water softeners or water fi lters. The manual is designed to aid water treatment
equipment manufacturers in the selection of the various control valve options. Information in this manual is different than what is
needed for installation and servicing of a particular water treatment system. This manual is not intended to be used as a manual for
a complete water softener or fi lter. Certain parts of the manual will serve as aids to manufacturers in the writing and layout of the
manuals for installers and service personnel.
General Warnings
(Must appear in OEM’s manual)
The following general warnings and the specifi cations in Table 1 must appear in the OEM’s System Manual.
The control valve, fi ttings and/or bypass are designed to accommodate minor plumbing misalignments but are not designed to
support the weight of a system or the plumbing.
Do not use Vaseline, oils, other hydrocarbon lubricants or spray silicone anywhere. A silicone lubricant may be used on black
o-rings but is not necessary.
Avoid any type of lubricants, including silicone, on the clear lip seals.
The nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench. If necessary a pliers can be
used to unscrew the nut or cap. Do not use a pipe wrench to tighten or loosen nuts or caps. Do not place a screwdriver in the slots on
caps and/or tap with a hammer.
Do not use pipe dope or other sealants on threads. Use tefl on tape on threaded inlet, outlet and drain fi ttings. Tefl on tape is not
necessary on the nut connection or caps because of o-ring seals.
After completing any valve maintenance involving the drive assembly or the drive cap assembly and pistons, unplug power source
jack from the printed circuit board (black wire) and plug back in. This resets the electronics and establishes the service piston
position.
All plumbing should be done in accordance with local plumbing codes. The pipe size for the drain line should be a minimum of ½
”
.
Backwash fl ow rates in excess of 7 gpm or length in excess of 20
’
require ¾
”
drain line.
Solder joints near the drain must be done prior to connecting the drain line fl ow control fi tting. Leave at least 6
”
between the drain
line control fi tting and solder joints when soldering pipes that are connected on the drain line control fi tting. Failure to do this could
cause interior damage to the drain line fl ow control fi tting.
When assembling the installation fi tting package (inlet and outlet), connect the fi tting to the plumbing system fi rst and then attach
the nut, split ring and o-ring. Heat from soldering or solvent cements may damage the nut, split ring or o-ring. Solder joints should
be cool and solvent cements should be set before installing the nut, split ring and o-ring. Avoid getting primer and solvent cement on
any part of the o-rings, split rings, bypass valve or control valve.
Plug into an electrical outlet. Note: All electrical connections must be connected according to local codes. (Be certain the outlet is
uninterrupted.)
Install grounding strap on metal pipes.
Summary of Contents for Water Specialist WS1TC
Page 13: ...WS1TC WS1 25 TC Manual Page 13 Figure 3 Figure 4 Figure 1 Figure 2...
Page 21: ...WS1TC WS1 25 TC Manual Page 21 Drawings and Part Numbers...
Page 33: ...WS1TC WS1 25 TC Manual Page 33 Flow Diagrams Service and Backwash...
Page 34: ...Page 34 WS1TC WS1 25 TC Manual Flow Diagrams Down ow Brine and Rinse...
Page 35: ...WS1TC WS1 25 TC Manual Page 35 Flow Diagrams Fill...
Page 44: ...Page 44 WS1TC WS1 25 TC Manual...
Page 45: ...WS1TC WS1 25 TC Manual Page 45...
Page 46: ...Page 46 WS1TC WS1 25 TC Manual...
Page 47: ...WS1TC WS1 25 TC Manual Page 47...