If the display shows “E1,” “E2” or “E3” (for error), call a service
technician.
MANUAL REGENERATION
NOTE:
For softeners, if brine tank does not contain
salt, fi ll with salt and wait at least 2 hours before
regeneration.
If you need to initiate a manual regeneration, either
immediately, or tonight at the preprogrammed time
(typically 2 a.m.), complete the following steps.
For Immediate Regeneration:
Press and hold UP and DOWN simultaneously until
valve motor starts (typically 3 seconds).
Arrow will point to Regen if a regen-
eration is expected “Tonight.”
To
shut off water
to the system, please position arrow handles as shown in the
bypass operation
diagram below. If your valve doesn’t look like the diagram below, contact your service technician for
instructions on how to shut off water.
NORMAL OPERATION
Treated
Water Exits
Supply Water
Enters
BYPASS OPERATION
Supply Water
Exits
Supply Water
Enters
For Regeneration Tonight:
Press and release UP and DOWN simultaneously
(notice that arrow points to Regen).
TO SET TIME OF
REGENERATION
For initial set-up or to make
adjustments, please complete
the steps as shown to the right.
Access this mode by pressing SET
HOUR and UP simultaneously for
3 seconds.
TO SET TIME OF DAY
In the event of a power outage, time
of day needs to be reset. All other
information will be stored in memory
no matter how long the power outage.
Please complete the steps as shown
to the right. To access this mode, press
SET HOUR.
1. Accessed by pressing SET HOUR
and UP simultaneously for 3
seconds.
2. Adjust time of regeneration hour
using the UP or DOWN. An arrow
points to PM during p.m. hours.
Simultaneously press SET HOUR
and DOWN to return to normal
operation.
1. Accessed by pressing SET
HOUR.
2. Adjust to the nearest hour
using UP or DOWN. An
arrow points to PM during
p.m. hours.
3. Press SET HOUR to
complete and return to
normal operation.
GENERAL OPERATION
When the system is operating
one of two displays will be
shown: time of day or days
until the next regeneration.
Pressing UP or DOWN will
toggle between the two
choices.
Arrow will point to Regen
if a regeneration is
expected “Tonight.”
➟
➟
or
Summary of Contents for Water Specialist WS1TC
Page 13: ...WS1TC WS1 25 TC Manual Page 13 Figure 3 Figure 4 Figure 1 Figure 2...
Page 21: ...WS1TC WS1 25 TC Manual Page 21 Drawings and Part Numbers...
Page 33: ...WS1TC WS1 25 TC Manual Page 33 Flow Diagrams Service and Backwash...
Page 34: ...Page 34 WS1TC WS1 25 TC Manual Flow Diagrams Down ow Brine and Rinse...
Page 35: ...WS1TC WS1 25 TC Manual Page 35 Flow Diagrams Fill...
Page 44: ...Page 44 WS1TC WS1 25 TC Manual...
Page 45: ...WS1TC WS1 25 TC Manual Page 45...
Page 46: ...Page 46 WS1TC WS1 25 TC Manual...
Page 47: ...WS1TC WS1 25 TC Manual Page 47...