5-3.Detailed setting mode
<How to enter to detailed setting mode>
<Auto reference function>
When CH2 function selected external input of auto reference, setting
value of switch output can be taken by external input or key operation.
The set point takes the flow rate when external input is turned on (or
key operation). When auto reference is executed, the switch setting of
CH2 becomes invalid.
mL
/
min
<Instantaneous flow rate display>
Press for 8 sec.
<Flow direction selection>
Press once.
<Auto reference function (CH2 setting)>
To instantaneous flow rate display
Not change to flow direction
Press once. (determination)
mL
/
min
Press once.
<Response time setting>
Press once. (determination)
Press once.
<Display speed selection>
Press once. (determination)
Press once.
<Sub-display selection>
Press once. (determination)
Press once.
<Displayed color selection>
Press once. (determination)
Press once.
<Hysteresis fixed value selection>
Press once. (determination)
Press once.
<Flow rate unit selection>
Press once. (determination)
Press once.
<Eco mode setting>
Press
Press once.
<Reset setting>
Press once. (determination)
Press once.
<
Model number display
>
Press once. (determination)
Press once.
Setting value
。
Setting value
。
Setting value
。
Setting value
。
Setting value
。
Setting value
。
Setting value
。
Setting value
。
Setting value
。
At instantaneous flow rate display, press
key for 8 sec. to enter to detailed
setting mode.
To auto reference
setting display
To response time
setting display
To display speed
setting display
To sub-display
setting display
To displayed color
setting display
To hysteresis fixed value
setting display
To flow rate unit
setting display
To eco mode
setting display
To
reset
setting display
To
model number
display
Input
point
Operation
mode
Description Operation
waveform
1-point input
[1]
(Flow rate
large side
ON)
ON when higher than input
point.
Set-point=input point
1
point
1-point input
[2]
(Flow rate
small side
ON)
OFF when higher than input
point.
Set-point=input point
2-point input
[1]
(Flow rate
large side
ON)
ON when higher than centre
value of two input points
Set-point=
(input input point2)/2
2-point input
[2]
(Flow rate
small side
ON)
OFF when higher than
centre value of two input
points
Set-point=
(input input point2)/2
2-point inside
(Range inside
ON)
ON when flow rate level is
within two input points.
Setpoint1=input point 1
Setpoint2=input point 2
2
point
2-point
outside
(Range
outside ON)
OFF when flow rate level is
within two input points.
Setpoint1=input point 1
Setpoint2=input point 2
Flow rate
ON
OFF
Input point
ON
OFF
Input point
Flow rate
ON
OFF
Input point 1
Input point 2
Flow rate
ON
OFF
Input point 1
Input point 2
Flow rate
ON
OFF
Input point 1
Input point 2
Flow rate
ON
OFF
Input point 2
Input point 1
Flow rate
-5-