Integrated indicator type (Stainless body)
Model no.
Descriptions
Integrated indicator type (Stainless body)
FSM2-[*1][*2][*3][*4]-[*5][*6]
Full
scale
flow
rate 005 010 020 050 100 200 500 101 201
005 500m L/m in
●
010 1L/m in
●
020 2L/m in
●
050 5L/m in
●
100 10L/m in
●
200 20
L/m in
●
500 50
L/m in
●
101 100
L/m in
●
Full scale
flow rate
Note 1
*4
201 200
L/m in
●
S06
Rc1/8 / Stainless
●
●
●
●
●
●
●
(only Air,
Ar)
Poet size/
Body
m aterial
*5
S08
Rc1/4 / Stainless
●
●
●
(only Air, A r)
Type of display
Dual (2×4-digit 7-segm ent) Two-color LCD
Flow
rate
range
*3 F
0 to
500
mL/min
0 to
1000
mL/min
0 to
2.00
L/m in
0 to
5.00
L/m in
0 to
10.00
L/m in
0 to
20.0
L/m in
0 to
50.0
L/m in
0 to
100.0
L/m in
0 to
200
L/m in
Flow rate display
Note 1
、
2
Display resolution
1m L/m in
0.01L/m in
0.1L/m in
1L/m in
Flow rate range
9999999m L
99999.99L
999999.9L
9999999L
Display resolution
1m L
0.01L
0.1L
1L
Integrating function
Note 3
、
7
Integrating pulse output rate
5m L
10m L
0.02L
5m L 10m L
0.02L 5m L 10m L
2L
Blank Clean
air
(JIS B 8392-1.1.1 to 5.6.2)
, Com pressed air
(JIS B 8392-1.1.1
~
1.6.2)
, and Nitrogen gas
AR Argon
W orking fluid
Note 4
*6
C2 Carbon
dioxide
Maxim um working pressure
1.0MPa
Minim um working pressure
-0.09MPa
W ithstanding pressure
1.5MPa
Am bient tem perature / hum idity
0 to 50°C and 90% RH or less
Wo
rk
in
g
condi
tio
ns
W orking fluid tem perature
0 to 50°C (to be no dew condensation.)
Flow rate range
3 to 100% F.S.
Linearity (display / analog output)
±3% F.S. or less (25°C, 1 atm ospheric pressure)
Pressure characteristics
±5% F.S. or less (-0.09 to 0.7MPa, 25°C, 1 atm ospheric pressure criteria)
Tem perature characteristics
±0.2% F.S./°C or less (15 to 35°C, 25°C criteria)
A
ccur
acy
Repeatability ±1% F.S.
or
less
Response tim e
Note3
50m s
or
less
N
2 points (NPN open collector output, 50m A or less, voltage drop 2.4V or less)
Switch output
*1
P
2 points (PNP open collector output, 50m A or less, voltage drop 2.4V or less)
V
1 point (1 to 5V voltage output and connected load im pedance 50k
Ω
and over)
O
ut
put
Analog output
*2
A
1 point (4 to 20m A current output and connected load im pedance 300
Ω
or less)
V
DC12 to 24V (10.8 to 26.4V)
Power supply voltage
*2
A DC24V
(21.6 to 26.4V)
Current consum ption
Note8
50m A
or
less
Lead wire
φ
3.7
AW G26×5
Functions
Flow rate display, flow rate display-peak hold, switch output and analog output
,
O utside diam eter of insulator is
Φ
1.0
Installation attitude
Both vertical and horizontal
Strait piping section
Not required
Protective structure
Note 9
IEC standards IP40
Protective circuit
Note5
Power supply and switch output reverse connection protections, and switch output
load short-circuit protection
EMC
instruction
Acceptable goods
S06 Approx.
160g
Mass
(
O nly the m ain body
)
*5
S08 Approx.
200g
P70
Particle occurrence prevention
Note10
Clean specification
*7
P80
Oil treatm ent prohibited
Note11
-9-
Note1: Converted to volumetric flow at 20°C and 1 atmospheric pressure (101kPa)
Note2: Flow late display is only the read within rough
±
1%F.S.
Note3: Integranted flow display is reference value.
Note4: When using compressed air, use clean air complying with JIS B 8392-1:2003 class over 1.1.1 to 1.6.2. Compressed air from the compressor contains drainage (water, oxidized oil,
foreign matter, etc.). Install a filter
(
filtration rating
:
5µm
)
, air dryer
(
minimum pressure dew point 10
℃
or less
)
and oil mist filter(maximum oil concentration 0.1mg/m
3
) on the primary
side of the product to maintain product function.
When using for purposes other than compressed air, use dry gas that does not contain corrosive elements such as chlorine, sulfur or acids, and clean gas that does not contain dust
or oil mist.
Note5: The response time can be selected from 50ms to 1500ms.
Note6: Current consumption is different according to the state of the load.
Note7: Integrated flow value is reset by turning power off.
Note8: Current consumption is characteristics 24VDC and no load. It is changed by load. Please note it.
Note9
:
This product’s protective circuit is effective only for specific incorrect connections and load short-circuits. It does not necessarily provide protection for all incorrect connections.
Note10:<P70>Particle occurrence prevention (It is washing of remove fat to surface of product before it wraps it. And heat seal wrapping to antistatic bag inside clean work
station.(Class:100 or more ))
Note11:<P80>Oil treatment prohibited (In addition to the P70 specification, It is washing of removing fat to touching gas. Please refer, Touching gas material is internal structural chart.)
Discontinue