- 91 -
• a = 6: When printing speed is specified
Setting Status
Sending Data
Stored
Value
Print Density
1st Byte
2nd Byte
3rd Byte
4th Byte
5th Byte
1
Speed level 1
49 (“1”)
—
—
—
—
2
Speed level 2
50 (“2”)
—
—
—
—
3
Speed level 3
51 (“3”)
—
—
—
—
4
Speed level 4
52 (“4”)
—
—
—
—
5
Speed level 5
53 (“5”)
—
—
—
—
6
Speed level 6
54 (“6”)
—
—
—
—
7
Speed level 7
55 (“7”)
—
—
—
—
8
Speed level 8
56 (“8”)
—
—
—
—
9
Speed level 9
57 (“9”)
—
—
—
—
• a = 201: When ACK output position is specified
Setting Status
Sending Data
Stored
Value
ACK Output
Position
1st Byte
2nd Byte
3rd Byte
4th Byte
5th Byte
1 ACK-in-Busy
49
(“1”)
— — — —
2 ACK-while-Busy
50
(“2”)
—
— —
—
3
ACK-after- Busy
51 (“3”)
—
—
—
—
• a = 202: Input buffer full Busy output/cancel timing
At 45 Byte setting (At MSW1-2 ON setting)
Setting Status
Sending Data
Stored
Value
BUSY
Output/Cancel
1st Byte
2nd Byte
3rd Byte
4th Byte
5th Byte
1 16/26 49
(“1”)
— — — —
2 16/36 50
(“2”)
— — — —
3 8/26
51
(“3”)
—
—
—
—
4 8/36
52
(“4”)
—
—
—
—
At 4k Byte setting (At MSW1-2 OFF setting)
Setting Status
Sending Data
Stored
Value
BUSY
Output/Cancel
1st Byte
2nd Byte
3rd Byte
4th Byte
5th Byte
1 128/256
49
(“1”)
— —
— —
2 128/512
50
(“2”)
— —
— —
3 72/256
51
(“3”)
—
—
—
—
4 72/512
52
(“4”)
—
—
—
—