- 90 -
fn = 6: Function 6 Sending the Set Customized Value
GS (E pL pH fn a fn = 6
[Code]
<1d>H<28>H<45>H pL pH fn a
[Range]
(pL + pH x256) = 2 : (pL = 2, pH = 0)
fn = 6
a = 5, 6, 201, 202
[Outline]
• Sends the set value of customized value set by “a”.
Hex.
No. of Data
Header 37H 1
ID 27H 1
Customized value No.
30H ~ 39H
1 ~ 3
Separation number
1FH
1
Customized value
30H ~ 39H
1 ~ 5
NULL 00H 1
• Configuration of customized value No.
Sending Data
a
1st Byte
2nd Byte
3rd Byte
5 53
(“5”)
—
—
6 54
(“6”)
—
—
201
50 (“2”)
48 (“0”) 49
(“1”)
202
50 (“2”)
48 (“0”) 50
(“2”)
• a = 5: When print density is specified
Setting Status
Sending Data
Stored
Value
Density
1st Byte
2nd Byte
3rd Byte
4th Byte
5th Byte
65530
70%
54 (“6”)
53 (“5”)
53 (“5”)
51 (“3”) 48
(“0”)
65531
75%
54 (“6”)
53 (“5”)
53 (“5”)
51 (“3”) 49
(“1”)
65532
80%
54 (“6”)
53 (“5”)
53 (“5”)
51 (“3”) 50
(“2”)
65533
85%
54 (“6”)
53 (“5”)
53 (“5”)
51 (“3”) 51
(“3”)
65534
90%
54 (“6”)
53 (“5”)
53 (“5”)
51 (“3”) 52
(“4”)
65535
95%
54 (“6”)
53 (“5”)
53 (“5”)
51 (“3”) 53
(“5”)
0
Basic
density
48 (“0”)
—
—
—
—
1 105%
49
(“1”) — — — —
2 110%
50
(“2”) — — — —
3 115%
51
(“3”) — — — —
4 120%
52
(“4”) — — — —
5 125%
53
(“5”) — — — —
6 130%
54
(“6”) — — — —
7 135%
55
(“7”) — — — —
8 140%
56