- 146 -
• MSW 3-3: Reset signal
[Outline]
Selects whether to reset the printer by the signal of parallel I/F 31 Pin.
OFF (0)
ON (1)
Reset signal
Valid
Invalid
Operation at ON (1): Used as Reset signal.
Operation at OFF (0): Not used as Reset signal.
[Default] OFF(0) [Valid]
• MSW 3-4: Reserved (OFF(0)Fixed)
• MSW 3-5: Reserved (OFF(0)Fixed)
• MSW 3-6: Reserved (OFF(0)Fixed)
• MSW 3-7: Reserved (OFF(0)Fixed)
• MSW 3-8: Clearing Head-Up Error
[Outline]
Selects the method of clearing Head-Up error.
OFF (0)
ON (1)
Resume Open Err
Close
Command
Operation at ON (1):
Printer clears error when it receives a command <DLE+ENQ+n> after detecting head-down.
Operation at OFF (0):
Printer automatically clears error when it detects head-down.
[Default] OFF(0) [Close]