confirm to which unit you are connected. The
Name
text field holds
a maximum of 20 characters.
Path
:
Configuration -> System
To access this area, select
Configuration
and then
System
from the menu
system.
Name
is the top option on the screen displayed, as shown in
Figure
31
.
Figure 31: Setting the system name
Console baud rate
You can change the Console baud rate from the same screen (
Figure 31
).
The default baud rate is 9600 and the available choices are 38400,
19200, 9600,
4800, 2400.
Modem init String
The Modem init string is the command to configure the modem. The
initialization string, typically Hayes commands, configures the modem’s
options for things like error correction, data compression and flow control
(as well as other parameters). The default is ATE0 which turns on echoing of
commands and long result codes and also selects blind dialing (does not
check for dial tone before dialing). Maximum entry is 20 characters.
Ethernet Connection Mode
Path
:
TVA -> Utilities -> System -> Set Enet Mode
1.
To set the Ethernet LAN mode, from the Console MI select
Utilities
, then
System
and finally
Set Enet Mode
.