Figure 9: Thermal Interface Material Application Pattern
Use only the correct heatsink for your CPU. CPU 1 uses heatsink UCSX-HS-M6-R and CPU 2 uses heatsink
UCSX-HS-M6-F.
Caution
Step 4
Attach the heatsink to the CPU fixture.
a) Grasp the heatsink by the fins (1, in the following illustration), align pin 1 location of the heatsink with the pin 1
location on the CPU fixture (2), then lower the heatsink onto the CPU fixture.
The heatsink is correctly oriented when the embossed triangle points to the CPU pin 1 location, as shown.
Make sure the rotating wires are in the unlocked position so that the feet of the wires do not impede installing
the heatsink.
Caution
Cisco UCS X210c M6 Compute Node Installation and Service Note
43
Servicing a Compute Node
Installing the CPU and Heatsink