28
3. Enter the
interface mgmt-ethernet
command.
Example
4. Enter the IP address of the management port followed by the net mask.
Example
5. Set the default gateway of the management port.
Example
6. Enable the management port with the
no shutdown
command. You can now telnet to your Topspin
360, or enter the IP address of your Topspin 360 in a Web browser to launch Chassis Manager.
Example
7. Save the configuration to preserve it between reboots.
Example
8. Attach an Ethernet cable from the management port to the Ethernet router or switch.
You are now ready to use the out-of-band Ethernet port to manage the system.
Obtain an IP Address with DHCP
1. Enter the
enable
command.
Example
2. Enter the
configure
command.
Example
3. Enter the
interface mgmt-ethernet
command.
Example
4. Enter the IP address of the management port followed by the net mask.
Example
Topspin-360(config)#
interface mgmt-ethernet
Topspin-360(config-if-mgmt-ethernet)#
ip address 10.10.0.22 255.255.255.0
Topspin-360(config-if-mgmt-ethernet)#
gateway 10.10.0.1
Topspin-360(config-if-mgmt-ethernet)#
no shutdown
Topspin-360(config-if-mgmt-ethernet)#
exit
Topspin-360(config)#
exit
Topspin-360#
copy running-config startup-config
Topspin-360>
enable
Topspin-360#
Topspin-360#
configure
Topspin-360(config)#
Topspin-360(config)#
interface mgmt-ethernet
Topspin-360(config-if-mgmt-ethernet)#
addr-option dhcp
Summary of Contents for TOPSPIN SFS 3012
Page 6: ...vi ...
Page 12: ...xii Phone 800 499 1473 Online Help Desk http support topspin com ...
Page 18: ...xviii ...
Page 22: ...4 ...
Page 26: ...8 7 Push the ejector lever up until it clicks into place Figure 2 3 Closing the Ejector Lever ...
Page 36: ...18 ...
Page 58: ...40 ...
Page 66: ...48 ...
Page 78: ...60 ...