Table 9: Environmental Specifications
Specification
Description
50 to 95°F (10 to 35°C)
Extended environment 41 to 104°F (5 to 40°C)
Derate the maximum temperature by 1°C per every 305 meters of altitude above
sea level.
Although the ASHRAE guidelines define multiple classes with different
operating ranges, the recommended temperature and humidity operating
range is the same for each class. The recommended temperature and
humidity ranges are:
Note
• Operating Temperature: 64.4°F to 80.6°F (18°C to 27°C)
Temperature, Operating
–40 to 149°F (–40 to 65°C)
Temperature, non-operating
(when the server is stored or transported)
8 to 90%
Humidity (RH), operating
5 to 93%
Humidity (RH), non-operating
(when the server is stored or transported)
0 to 10,000 feet
Altitude, operating
0 to 40,000 feet
Altitude, non-operating
(when the server is stored or transported)
5.5
Sound power level
Measure A-weighted per ISO7779 LwAd (Bels)
Operation at 73°F (23°C)
40
Sound pressure level
Measure A-weighted per ISO7779 LpAm (dBA)
Operation at 73°F (23°C)
Power Specifications
The power specifications for the supported power supply options are listed in the following section.
1050 W AC Power Supply
This section lists the specifications for each 1050 W AC power supply (Cisco part number
UCSC-PSU1-1050W).
Cisco Application Services Engine Hardware Installation Guide
86
Server Specifications
Power Specifications