Figure 46: Embedded RAID Interposer Cable-to-Drive Backplane Mapping, LFF 4-Drive Version
Figure 47: Embedded RAID Interposer Cable-to-Drive Backplane Mapping, SFF 10-Drive Version
Cisco 12G Modular SAS RAID Controller or HBA
This HW RAID option can control up to 10 SAS/SATA drives in the SFF 10-drive version and up to 4
SAS/SATA drives in the LFF 4-drive version.
This option requires that you have a SAS RAID or HBA card installed in internal mRAID riser 3. Use the
SAS/SATA cables that came with the server.
1. Connect SAS/SATA cable A1 from the A1 card connector to the A1 backplane connector.
2. Connect SAS/SATA cable A2 from the A2 card connector to the A2 backplane connector.
3. For SFF-10-drive servers only: Connect SAS/SATA cable B2 from the B2 card connector to the B2
backplane connector.
See the following figures that illustrate cable connections and which drives are controlled by each cable.
Note
Cisco Application Services Engine Hardware Installation Guide
95
Storage Controller Considerations
Storage Controller Considerations