4-2
PA-POS-2OC3 Two-Port Packet-over-SONET Port Adapter Installation and Configuration
OL-3028-06
Chapter 4 Configuring the PA-POS-2OC3
Configuring the Interfaces
To configure the new interfaces, proceed to the
“Configuring the Interfaces” section on page 4-2
Configuring the Interfaces
After you verify that the new PA-POS-2OC3 is installed correctly (the ENABLED LED goes on), use
the privileged-level
configure
command to configure the new interfaces. Have the following information
available:
•
IP addresses, if you plan to configure the interface for IP routing
•
MTU size
•
Framing mode
•
Transmit clock source
•
Loopback modes (if testing is required)
If you installed a new PA-POS-2OC3 or if you want to change the configuration of an existing interface,
you must enter configuration mode to configure the new interfaces. If you replaced a
PA-POS-2OC3 that
was previously configured, the system recognizes the new interfaces and brings each of them up in their
existing configurations.
For a summary of the configuration options available and instructions for configuring the interfaces on
a PA-POS-2OC3, refer to the appropriate configuration publications listed in the
Documentation” section on page iv
.
You execute configuration commands from the privileged level of the EXEC command interpreter, which
usually requires password access. (See the
“Using the EXEC Command Interpreter” section on page 4-1
for an explanation of the privileged level of the EXEC.) Contact your system administrator, if necessary,
to obtain password access.
On power up, the OC-3 interface on a new PA-POS-2OC3 is shut down. To enable the interfaces, you
must enter the
no shutdown
command in configuration mode. (See
Configuration” section on page 4-3
.) When the OC-3 interface is enabled (taken out of shutdown) with
no additional arguments, the default interface configuration file parameters look like those in
.
Table 4-1
PA-POS-2OC3 Configuration Default Values
Parameter
1
1.
These default parameters apply to the PA-POS-2OC3 in all supported platforms.
Configuration Commands
Default Value
MTU
mtu
bytes
(
no mtu
bytes
)
4470 bytes
Framing
pos framing sdh
(
no pos framing sdh
)
SONET framing
Loopback internal
loop internal
(
no loop internal
)
No internal loopback
Loopback line
loop line
(
no loop line
)
No line loopback
Transmit clocking source
clock source internal
clock source line
Loop timing
Cyclic redundancy checks
crc 16
crc 32
crc 16
SONET payload scrambling
pos scramble-atm
(
no pos
scramble-atm
)
No scrambling