1-18
Cisco ONS 15600 SDH Reference Manual, Release 9.0
78-18400-01
Chapter 1 Shelf and Backplane Hardware
1.11.2 OGI Cables
1.11.2 OGI Cables
The ONS 15600 SDH faceplate has OGI connectors that terminate in either SC, ST, or FC connectors.
shows the OGI to SC cable breakout for the STM-16 card.
Figure 1-14
OGI Cable Breakout
show the OGI pin breakout for the STM-16 card.
Table 1-3
Optical Card Ports and Line Rates
Card
Ports
Line Rate per Port
OC48/STM16 LR/LH 16 Port 1550;
OC48/STM16 SR/SH 16 Port 1310
4 physical interfaces; 4 ports per interface,
totalling 16 STM-16 ports per card
2488.32 Mbps (VC4-16c)
OC192/STM64 LR/LH 4 Port 1550;
OC192/STM64 SR/SH 4 Port 1310
4 physical interfaces; 1 port per interface,
totalling four STM-64 ports per card
9.95 Gbps (VC4-64c)
Any-Service Any-Port (ASAP) card
(STM-1, STM-3, STM-16, STM-64,
or Gigabit Ethernet)
4 physical interfaces; 1 to 4 ports per interface,
depending on the Pluggable Input/Output
Module used; totalling a maximum of four
STM-64 ports per card
Up to 9.95 Gbps (VC4-64c)
Breakout protection
SC connector
SC key feature
P1
P2
P3
P4
P5
P6
P7
P8
96520